20
Programming Guide
Partition Timers
Refer to the
on page 65 for alternate entry/exit and bell cut-off timer programming.
System Programming
[742]
Partition 2 Options
Option
OFF
ON
[1]
Auto-arm on time
Disabled
Enabled
[2]
Auto-arm on no movement
Disabled
Enabled
[3]&[4]
Auto-arm arming mode
See Table
See Table
[5]
Switch to stay arming if no entry delay zone is opened
Disabled
Enabled
[6]
Follow zones become entry delay 2 when delay zone is bypassed
Disabled
Enabled
Section Data
Description
[745]
____/____/____
(000 to 255) seconds
Partition 1 exit delay (default 060)
[746]
____/____/____
(000 to 255) seconds
Partition 2 exit delay (default 060)
[747]
____/____/____
(000 to 255) minutes
Partition 1 bell cut-off (default 004)
[748]
____/____/____
(000 to 255) minutes
Partition 2 bell cut-off (default 004)
[749]
____/____/____
(000 to 255) x 15 minutes
Partition 1 no movement (default 000)
[750]
____/____/____
(000 to 255) x 15 minutes
Partition 2 no movement (default 000)
[761]
____/____:____/___
HH: MM
Auto-arm on time Partition 1 (default 00:00)
[762]
____/____:____/____
HH: MM
Auto-arm on time Partition 2 (default 00:00)
[700]
General System Options
Option
OFF
ON
[2]
Battery charging (350mA or 700mA)*
350mA
700mA
[3]
Audible trouble warning (except AC failure)
Disabled
Enabled
[4]
Audible trouble warning on AC failure
Disabled
Enabled
[6]
Exit delay termination
Disabled
Enabled
[7]
Tamper supervision on the bus module
Disabled
Enabled
* Does not apply to SP4000 systems
[702]
Panic Options
Option
OFF
ON
[1]
Panic 1
Disabled
Enabled
[2]
Panic 2
Disabled
Enabled
[3]
Panic 3
Disabled
Enabled
[4]
Panic 1: Report only or audible alarm
Report only
Audible
[5]
Panic 2: Report only or audible alarm
Report only
Audible
[6]
Panic 3: Report only or audible alarm
Report only
Audible
[703]
Arming/Disarming Options
Option
OFF
ON
[5]
Restrict arming on battery failure
Disabled
Enabled
[6]
Restrict arming on tamper failure (Zone + Bus Module
+ Wireless PGM)
Disabled
Enabled
[7]
Restrict arming on wireless supervision trouble (Wireless zones +
Wireless PGM)*
Disabled
Enabled
* Does not apply to SP4000 systems.
[704]
Arming/Disarming Options
Option
OFF
ON
[1]
Regular arming switches to force arming
Disabled
Enabled
[2]
Stay arming switches to stay force arming
Disabled
Enabled
[3]
Sleep arming switches to sleep force arming
Disabled
Enabled
[3]
[4]
OFF
OFF
Regular
OFF
ON
Sleep
ON
OFF
Stay