![Paradox MG-RCV3 Reference And Installation Manual Download Page 24](http://html1.mh-extra.com/html/paradox/mg-rcv3/mg-rcv3_reference-and-installation-manual_3620449024.webp)
20
Reference & Installation Manual
7.0 System Reset
Performing a system reset will reset all the MG-RCV3 sections to their factory
default settings.
8.0 List of Programming Sections
How to reset the MG-RCV3.
1. Remove the power connections from the MG-RCV3 (“
RED
” and “
BLK
”).
2. Press and hold the MG-RCV3’s “
PROGRAM
” button (refer to Figure 2.2 on
page 6) while reconnecting the power connections to the MG-RCV3. The
keypad will beep.
3. Wait approximately 1 second and release the “
PROGRAM
” button. The MG-
RCV3’s red LED will flash quickly for approximately 5 seconds.
Section
Description
[00]
Set the installer code
[01]
to
[08]
Assign a user to the MG-RCV3
[09]
to
[16]
• Assign a remote control
• Delete an assigned remote control
[17]
to
[24]
Remote Control Button Programming
Options [1] to [3]: Remote control arming options
Option [4]: Enable button PGM
Option [5]: Enable button
PGM
Option [6]: Enable button
PGM
Option [7]: Enable button
PGM
Option [8]: Enable Panic
[25]
Panic Alarm Outputs
Option [0]: No PGM output on panic alarm
Option [1]: Toggle PGM 1 on panic alarm
Option [2]: Toggle PGM 2 on panic alarm
Option [3]: Toggle PGM 3 on panic alarm
Option [4]: Toggle PGM 4 on panic alarm
MGRCV3ES_EI01.fm Page 20 Wednesday, May 4, 2005 3:27 PM