background image

Magellan Wireless Expansion Module

17

5.1 PGM Connection

The PGMs are connected as detailed in Figure 2.4 on page 8.

5.2 PGM Output Timer

SECTIONS

 

[27]

 

TO

 

[30]

This feature determines whether an activated PGM will toggle back to its 
original state after a specified time period has elapsed or when toggled 
(latched) manually. Each PGM output can be programmed with a unique 
output timer. Sections [27] to [30] correspond to PGM 1 to PGM 4 respectively. 
In the section corresponding to the desired PGM, enable one of the options 
from [0] to [8] (refer to Table 5.1 on page 17) by pressing the corresponding 
keypad key.

How to set the PGM output timer.

In step 4 in section 3.2 on page 10:

1. Enter a section number between 

[27]

 and 

[30]

.

2. Enable only one option from 

[0]

 to 

[8]

 (refer to Table 5.1 on page 17).

3. Press 

[

ENTER

]

.

Table 5.1: PGM Output Timer

Key 

[0]

 ON

= Latched

Key 

[1]

 ON

= 1 second

Key 

[2]

 ON

= 5 seconds (default)

Key 

[3]

 ON

= 10 seconds

Key 

[4]

 ON

= 20 seconds

Key 

[5]

 ON

= 40 seconds

Key 

[6]

 ON

= 60 seconds

Key 

[7]

 ON

= 2 minutes

Key 

[8]

 ON

= 4 minutes

MGRCV3ES_EI01.fm  Page 17  Wednesday, May 4, 2005  3:27 PM

Summary of Contents for MG-RCV3

Page 1: ...Wireless Expansion Module V1 0 Reference Installation Manual MG RCV3 Stand Alone System MGRCV3ES_EI01 fm Page 3 Wednesday May 4 2005 3 27 PM...

Page 2: ...MGRCV3ES_EI01 fm Page 2 Wednesday May 4 2005 3 27 PM...

Page 3: ...ser Parameters 11 Assign a User to the MG RCV3 Esprit mode only 12 Assign a Remote Control 12 Program the Remote Control Buttons 13 Remote Control Button PGM Options 15 Delete an Assigned User Esprit...

Page 4: ...Remote Control Button Options 14 RC Button PGM Options 15 PGM Output Timer 17 Panic Outputs 18 Panic Lockout Timer 19 List of Figures Mounting 5 Connection with an Esprit Control Panel 6 Stand Alone...

Page 5: ...puts PGMs In stand alone mode the remote controls will only activate the four on board PGMs 1 1 Technical Specifications Di pole antenna Error Correction Algorithm Compatibility Any Magellan wireless...

Page 6: ...nnect the MG RCV3 2 1 Location The location of the MG RCV3 affects its performance In order to ensure the best possible signal reception the following list of location criteria should be respected whe...

Page 7: ...vironment is too noisy the module s RX LED will illuminate refer to Figure 2 2 on page 6 and will remain illuminated until the module is powered up again In such cases power down the MG RCV3 change it...

Page 8: ...as a stand alone module connect the module using an external 12Vdc power supply that is equipped with a backup battery connector refer to Figure 2 3 on page 7 8 Verify the environment noise surroundin...

Page 9: ...Magellan Wireless Expansion Module 5 Figure 2 1 Mounting MGRCV3ES_EI01 fm Page 5 Wednesday May 4 2005 3 27 PM...

Page 10: ...6 Reference Installation Manual Figure 2 2 Connection with an Esprit Control Panel Refer to Figure 2 4 on page 8 for PGM connections MGRCV3ES_EI01 fm Page 6 Wednesday May 4 2005 3 27 PM...

Page 11: ...Magellan Wireless Expansion Module 7 Figure 2 3 Stand Alone Connection Refer to Figure 2 4 on page 8 for PGM connections MGRCV3ES_EI01 fm Page 7 Wednesday May 4 2005 3 27 PM...

Page 12: ...to an Esprit security system all the programming sections detailed in this manual apply When programming a MG RCV3 in stand alone mode only the sections detailed in Table 3 1 on page 9 apply Please no...

Page 13: ...can be selected When using Esprit 636 or 646 keypads the keys display the selected setting by illuminating the corresponding key Press the key representing the desired setting and then press ENTER to...

Page 14: ...RCV3 The installer code can be either four or six digits in length refer to section 4 1 on page 10 and each digit can be any value between zero and nine How to program 1 Press the MG RCV3 s PROGRAM bu...

Page 15: ...he relationship between the user parameter sections Assign the user to the MG RCV3 Assign a remote control Define the remote control buttons How to set the installer code In step 4 in section 3 2 on p...

Page 16: ...rrespond to users 1 to 8 respectively refer to Table 4 1 on page 11 Each time a remote control s button is pressed it transmits its RF code to the MG RCV3 which contains the corresponding user informa...

Page 17: ...to perform a specific action Enable or disable options 1 to 8 refer to Table 4 3 on page 14 by pressing the corresponding keypad key Figure 4 2 Remote Control Button Identification How to program a re...

Page 18: ...r Arm Button Regular Arm Off Off On Button Instant Arm On Off On Button Instant Arm Button Stay Arm Off On On Button Regular Arm Button Stay Arm On On On Button Stay Arm RC Button PGM Enabling refer t...

Page 19: ...output will be triggered by enabling and disabling options 1 to 4 refer to Table 4 4 on page 15 This feature is a global feature therefore if button is programmed to toggle the PGM 3 output then butto...

Page 20: ...ns such as opening a garage door when a remote control button is pressed For the PGM locations refer to Figure 2 4 on page 8 PGM 1 and PGM 2 Two 150mA PGM transistor outputs PGM 3 Form C relay output...

Page 21: ...4 respectively In the section corresponding to the desired PGM enable one of the options from 0 to 8 refer to Table 5 1 on page 17 by pressing the corresponding keypad key How to set the PGM output ti...

Page 22: ...Panic Lockout Timer Esprit mode only SECTION 26 OPTIONS 0 TO 4 When a remote control activates a panic alarm the MG RCV3 can be programmed to ignore any incoming remote control RF signals for a specif...

Page 23: ...ne option from 0 to 4 refer to Table 6 2 on page 19 3 Press ENTER Table 6 2 Panic Lockout Timer Key 0 ON No RF signal lockout on panic alarm default Key 1 ON 30 second RF signal lockout on panic alarm...

Page 24: ...s red LED will flash quickly for approximately 5 seconds Section Description 00 Set the installer code 01 to 08 Assign a user to the MG RCV3 09 to 16 Assign a remote control Delete an assigned remote...

Page 25: ...alarm 27 to 30 PGM Output Timers Option 0 Latched Option 1 1 second Option 2 5 seconds Option 3 10 seconds Option 4 20 seconds Option 5 40 seconds Option 6 60 seconds Option 7 2 minutes Option 8 4 mi...

Page 26: ...rect or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from...

Page 27: ...MGRCV3ES_EI01 fm Page 23 Wednesday May 4 2005 3 27 PM...

Page 28: ...780 Industriel Blvd Saint Eustache Quebec J7R 5V3 CANADA Tel 450 491 7444 Fax 450 491 2313 www paradox ca PRINTED IN CANADA 05 2005 MGRCV3ES EI01 MGRCV3ES_EI01 fm Page 24 Wednesday May 4 2005 3 27 PM...

Reviews: