EVOHD+ Installation Guide
73
Appendix 2: Contact ID Report Code List
If using the Ademco contact ID format, enter the two-digit hexadecimal value (under the column heading
Value
intable 18) to program the desired report codes into
sections
[0201]
to
[0296]
,
[0701]
to
[0832]
,
[2001]
to
[2199]
, and
[3900]
to
[3999]
.
Table 18: List of Ademco contact ID report codes
Type
CID # Reporting Code
Value
Me
d
ic
a
l A
la
rm
s
(100
)
100
Medical alarm
01
101
Personal emergency
02
102
Fail to report in
03
Fi
re
A
la
rm
s
(110
)
110
Fire Alarm
04
111
Smoke
05
112
Combustion
06
113
Water Flow
07
114
Heat 08
115
Pull Station
09
116
Duct
0A
117
Flame
0B
118
Near Alarm
0C
Pa
n
ic
A
la
rm
s
(120
)
120
Panic alarm
0D
121
Duress
0E
122
Silent
0F
123
Audible
10
124
Duress - access granted
11
125
Duress - egress granted
12
Bur
g
lar Alarm
s
(1
30)
130
Burglary
13
131
Perimeter
14
132
Interior
15
133
24-hour
16
134
Entry/exit
17
135
Day/night
18
136
Outdoor
19
137
Tamper
1A
138
Near alarm
1B
139
Intrusion verifier
1C
Gen
e
ra
l A
la
rm
s
(1
40)
140
General alarm
1D
141
Polling loop open
1E
142
Polling loop short
1F
143
Extension module failure
20
144
Sensor tamper
21
145
Expansion module tamper
22
146
Silent burglary
23
147
Sensor supervision failure
24
24-h
o
ur Non-
bur
g
lar
y
(15
0
& 16
0)
150
24-hour non-burglary
25
151
Gas detected
26
152
Refrigeration
27
153
Loss of heat
28
154
Water leakage
29
155
Foil break
2A
156
Day trouble
2B
157
Low bottled gas level
2C
158
High temperature
2D
24-h
o
u
r N
o
n-bur
g
lar
y
(150
& 16
0) (con
t.
)
159
Low temperature
2E
161
Loss of air flow
2F
162
Carbon monoxide detected
30
163
Tank level
31
Fi
re
S
u
p
e
rv
is
o
ry
(
20
0
)
200
Fire supervisory
32
201
Low water pressure
33
202
Low CO2
34
203
Gate valve sensor
35
204
Low water level
36
205
Pump activated
37
206
Pump failure
38
S
y
st
em
T
ro
u
b
les
(3
00
&
31
0
)
300
System trouble
39
301
AC loss
3A
302
Low system battery
3B
303
RAM checksum bad
3C
304
ROM checksum bad
3D
305
System reset
3E
306
Panel program changed
3F
307
Self-test failure
40
308
System shutdown
41
309
Battery test failure
42
310
Ground fault
43
311
Battery missing/dead
44
312
Power supply over current
45
313
Engineer reset
46
So
u
n
d
e
r/
Re
la
y
T
ro
u
b
le
s
(320)
320
Sounder relay
47
321
Bell 1
48
322
Bell 2
49
323
Alarm relay
4A
324
Trouble relay
4B
325
Reversing relay
4C
326
Notification appliance chk. #3
4D
327
Notification appliance chk. #4
4E
Table 18: List of Ademco contact ID report codes
Type
CID # Reporting Code
Value
S
y
st
e
m
P
e
ri
ph
er
a
l T
ro
u
bl
es
(330 &
340
)
330
System peripheral
4F
331
Polling loop open
50
332
Polling loop short
51
333
Expansion module failure
52
334
Repeater failure
53
335
Local printer paper out
54
336
Local printer failure
55
337
Exp. module DC low
56
338
Exp. module low batt
57
339
Exp. module reset
58
341
Exp. module tamper
59
342
Exp. module AC lost
5A
343
Exp. module self-test fail
5B
344
RF receiver jam detected
5C
C
o
mmunic
a
tion T
roub
les
(
35
0
)
350
Communication 5D
351
Telco fault 1
5E
352
Telco fault 2
5F
353
Long range radio
60
354
Fail to communicate
61
355
Loss of radio supervision
62
356
Loss of central polling
63
357
Long range radio VSWR
problem
64
P
rot
ec
ti
on
L
o
op
T
roub
les
(3
70)
370
Protection loop
65
371
Protection loop open
66
372
Protection loop short
67
373
Fire trouble
68
374
Exit error alarm
69
375
Panic zone trouble
6A
376
Hold-up zone trouble
6B
377
Swinger trouble
6C
378
Cross-zone trouble
6D
S
e
nsor T
roub
les
(
380
&
3
9
0
)
380
Sensor trouble
6E
381
Loss of supervision - RF
6F
382
Loss of supervision - RPM
70
383
Sensor tamper
71
384
RF transmitter low battery
72
385
Smoke detector hi sensitivity
73
386
Smoke detector low sensitivity
74
387
Intrusion detector hi
sensitivity
75
388
Intrusion detector low
sensitivity
76
389
Sensor self-test failure
77
391
Sensor watch trouble
78
392
Drift compensation error
79
393
Maintenance alert
7A
Table 18: List of Ademco contact ID report codes
Type
CID # Reporting Code
Value
Summary of Contents for EVOHD+