EVOHD+ Installation Guide
71
Global zone shutdown
1 574
Group bypass
CG
Close area
Duress alarm
1 121
Duress
HA
Hold-up alarm
Zone shutdown (##)
1 57A
Zone bypass
UB
Untyped zone bypass
Zone tampered (##)
1 144
Sensor tamper
TA
Tamper alarm
Zone tamper restore (##)
3 144
Sensor tamper restore
TR
Tamper restoral
Keypad lockout
1 421
Access denied
JA
User code tamper
AC failure
1 3A1
AC loss
AT
AC trouble
Battery failure
1 3A9
Battery test failure
YT
System battery trouble
Auxiliary supply trouble
1 3AA
System trouble
YP
Power supply trouble
Bell output current limit
1 321
Bell 1
YA
Bell fault
Bell absent
1 321
Bell 1
YA
Bell fault
Clock lost
1 626
Time/date inaccurate
JT
Time changed
Fire loop trouble
1 373
Fire trouble
FT
Fire trouble
Panel tamper
1 144
Sensor tamper
TA
Tamper alarm
TLM trouble restore
3 351
Telco 1 fault restore
LR
Phone line restoral
AC failure restore
3 3A1
AC loss restore
AR
AC restoral
Battery failure restore
3 3A9
Battery test restore
YR
System battery restoral
Auxiliary supply trouble restore
3 3AA
System trouble restore
YQ
Power supply restored
Bell output current limit restore
3 321
Bell 1 restore
YH
Bell restored
Bell absent restore
3 321
Bell 1 restore
YH
Bell restored
Clock programmed
3 625
Time/date reset
JT
Time changed
Fire loop trouble restore
3 373
Fire trouble restore
FJ
Fire trouble restore
Panel tamper restore
1 373
Sensor tamper restore
FT
Tamper restoral
Combus fault
1 333
Expansion module failure
ET
Expansion trouble
Module tamper
1 145
Expansion module tamper
TA
Tamper alarm
Module ROM_RAM_error
1 3A4
ROM checksum bad
YF
Parameter checksum fail
Module TLM trouble
1 352
Telco 2 fault
LT
Phone line trouble
Module fail to communicate to monitoring station
1 354
Fail to communicate
YC
Communication fails
Printer fault
1 336
Local printer failure
VT
Printer trouble
Module AC failure
1 3A1
AC loss
AT
AC trouble
Module battery failure
1 3A9
Battery test failure
YT
System battery trouble
Module auxiliary supply trouble
1 3AA
System trouble
YP
Power supply trouble
Module IP receiver supervision
-
-
-
-
Module IP receiver fail to communicate
-
-
-
-
Module IP receiver unregistered
-
-
-
-
Direct light
-
-
-
-
Module Rf Interference
1 344
RF receiver Jam
XQ
RF Jamming
Module low voltage
-
-
-
-
Module self-test error
-
-
-
-
Module LAN trouble
-
-
-
-
Module WAN trouble
-
-
-
-
Combus fault restore
3 333
Expansion module failure restore
ER
Expansion restoral
Panel tamper restore
3144
Sensor tamper restore
TR
Tamper Restoral
Module tamper restore
3 145
Expansion module tamper restore
TR
Tamper restoral
Module ROM_RAM_error restore
3 3A4
ROM checksum bad restore
YG
Parameter changed
Module TLM restore
3 352
Telco 2 fault restore
LR
Phone line restoral
Early to arm by user
3 451
Early to close
CK
Early to close
Late to arm by user
3 452
Late to close
CJ
Late to close
Zone excluded on Force arming
1 57A
Zone bypass
XW
Zone forced
System Event
Default Contact ID Report Code
(when using sections
[4032]
to
[4037]
)
Default SIA Report Code
(when using sections
[4032]
to
[4037])
Summary of Contents for EVOHD+
Page 1: ...EVOHD Installation Guide High Security Access System...
Page 86: ......