32
EVOHD+ Installation Guide
Timed Auto-Arming
(default =
disabled
) The control panel arms the selected partition every day at the time set. A 60-second Exit Delay (default value) triggers before the partition arms.
It can be cancelled or postponed by entering a valid access code. If zones are open, the control panel arms the partition and considers all open zones as temporarily
bypassed (except 24hr. zones). The control panel transmits the Auto-Arming report code programmed in section
[3910]
. The control panel will transmit the
Late to
Close
report code programmed in section
[3912].
Enable option
[1]
in the desired section:
Auto-Arm Timer
Enter the time when the partition should arm in the desired section:
Postpone Auto-Arming
(default =
000
) It is possible to postpone auto-arming for a preset amount of time by entering a valid user code during the exit delay. The delay is set by entering a
number between 001 and 255 in the appropriate section. That number represents for how many increments of 15 minutes the arming will be postponed.
Partition 1:
[3122]
Partition 3:
[3322]
Partition 5:
[3522]
Partition 7:
[3722]
Partition 2:
[3222]
Partition 4:
[3422]
Partition 6:
[3622]
Partition 8:
[3822]
Partition 1:
[3101]
Partition 3:
[3301]
Partition 5:
[3501]
Partition 7:
[3701]
Partition 2:
[3201]
Partition 4:
[3401]
Partition 6:
[3601]
Partition 8:
[3801]
Partition 1:
[3120]
Partition 3:
[3320]
Partition 5:
[3520]
Partition 7:
[3720]
Partition 2:
[3220]
Partition 4:
[3420]
Partition 6:
[3620]
Partition 8:
[3820]
Summary of Contents for EVOHD+
Page 1: ...EVOHD Installation Guide High Security Access System...
Page 86: ......