Chime zones

Zones 1 to 6, as well as the local keypad zones, can be programmed

as 

chime

zones. A chime zone "advises" you when it is opened by

creating a rapid intermittent beep tone. To turn on the "chime zone"

feature, press on the selected zone key for three seconds until the

intermittent chime beep is heard. This means that the chime feature

has been activated. If a continuous beep is heard, this means that

the chime is "off". (The keypad zone chime is enabled by pressing

key 

[8]

.)

If you have more than one keypad in your system, please "chime"

program each keypad separately. Keypad chimes must be repro-

grammed if the panel suffers total power loss. 

CHIME KEYS

:

Key [1]-[6]

Turns chime "

ON

" or "

OFF

" in zones numbered 1-6.

Key [8]

Turns the chime "

ON

" and "

OFF

" for the zone connected to

this keypad.

Each keypad must be programmed independently.

PANEL BUZZER MUTE

:

Key [9]

Turns keypad sounder "

ON

" and "

OFF

" (intermittent beep

means 

MUTE

is activated, and keypad sounder is "

OFF

".

Depress for 2 seconds to disable.)

Trouble Display [

TRBL

]

AC power failure will be communicated to you by the illumination of

the keypad 

[

TRBL

]

indicator. If you are unable to find the cause of AC

power loss, contact your installer/alarm company immediately.

IMPORTANT: 

Keep this information in a secure location.

ZONE DESCRIPTION

24Hr

Bypass Enabled

Zone 1:

l

l

Zone 2:

l

l

Zone 3:

l

l

Zone 4:

l

l

Zone 5:

l

l

Zone 6:

l

l

24Hr

Fire

Zone 7:

l

l

Zone 8:

11

10

UM727

UM727

Summary of Contents for Esprit 727

Page 1: ...our installer deal with it Programmable chime zones Pressing for 3 sec any of these keys will activate chime zones intermittent beeps or de activate chime zones continuous beeps SOFTWARE 3 1 AND OVER...

Page 2: ...or build ing that you want to protect can be divided into up to 8 zones and controlled by up to 5 keypads All the security operations you need to access will be right at your fingertips The ESPRIT key...

Page 3: ...es 4 6 priority 4 can arm disarm the system and User Code 7 priority 5 is an arm only access code Master and User Code programming The Esprit control panel can be programmed to accept up to 7 user cod...

Page 4: ...odes the 10 key represents the digit 0 2 STAY arming STAY MASTER CODE OR USER CODES 1 2 3 partial system arming STAY arming allows you to remain in the protected area while par tially arming the syste...

Page 5: ...nes have been bypassed If you make an error enter ing zone numbers press CLEAR and key in zones again Pressing CLEAR once more will exit the bypass mode without saving any bypass entries in memory To...

Page 6: ...d an alarm or that were open upon alarm Up to 15 levels of alarm history can be stored in memory Each level of memory is retrieved by repeatedly pressing the MEM key If the END REJECTION beep is heard...

Page 7: ...ed if the panel suffers total power loss CHIME KEYS Key 1 6 Turns chime ON or OFF in zones numbered 1 6 Key 8 Turns the chime ON and OFF for the zone connected to this keypad Each keypad must be progr...

Page 8: ...for 2 seconds Armed LED will flash The PGM Programmable Output function if applicable is and is activated by SYSTEM TIMES Entering and exiting your premises is permitted through doors that you and you...

Page 9: ...ages due to causes beyond the control of Paradox Security Systems such as lightning excessive voltage mechanical shock or water damage LIABILITY Under no circumstances shall Paradox Security Systems b...

Reviews: