![Paradox Esprit 727 User Manual Download Page 5](http://html2.mh-extra.com/html/paradox/esprit-727/esprit-727_user-manual_3603757005.webp)
above.) Also, when system is stay armed, pressing key
[10]
will acti-
vate an exit delay and then return the system to
STAY ARM
status, elim-
inating the need to disarm and then
STAY ARM
the system again.
(4) MANUAL BYPASS arming
[
BYP
]
+
MASTER CODE
OR
USER CODES
1, 2, 3
(Arms the system while bypassing defective zones and/or zones you
wish to leave open)
When you bypass a zone, it is no longer protected by the security
system. It will not generate an alarm on the control panel. You may
not wish to arm the entire system when, for example, workers are
renovating your basement, or you require access to a side door, or
for any other reason you need to leave a zone open while arming the
system. If a component of your security system is damaged, it can
also be bypassed until repairs are made. Manual bypass arming
instructs the control panel to ignore zones that you designate "open",
so that the rest of the system can still be armed. (Based on your
instructions, only zones that your installer has programmed "bypass-
enabled" can be bypassed during manual bypass arming, "away"
arming or "stay" arming. Please note that
the fire zone can never
be bypassed and zone 8 is always bypass-enabled
.)
Press the bypass
[
BYP
]
key, followed by your
MASTER CODE
or
USER
CODE
1
(
2
OR
3
). You are now in "bypass" mode.
[
BYP
]
and
[
ENTER
]
will
be illuminated. Enter the key numbers corresponding to the zones
you wish to leave open (1-6, 8). Press twice on a key if you wish to
undo a zone selection. If you have entered the correct zone bypass
information, press
[
ENTER
]
. The
[
BYP
]
key light will remain on indi-
cating that zones have been bypassed. If you make an error enter-
ing zone numbers, press
[
CLEAR
]
and key in zones again. (Pressing
[
CLEAR
]
once more will exit the bypass mode, without saving any
bypass entries in memory.)
To cancel zone bypass entries you have just made, press
[
BYP
]
+
CODE
+
[
CLEAR
]
+
[
ENTER
]
. Zone bypasses are cancelled every time
the panel is disarmed.
Using the "bypass recall" feature, you can reinstate the latest zone
bypass instructions saved in memory. Press
[
BYP
]
while in "manual
bypass arming" mode and the previous bypass status will be
reestablished. Even if you are in the process of entering new bypass
information on the keypad, one touch of the
[
BYP
]
key will override
this new information and reinstate the last zone bypass instructions
you saved.
(5) AWAY auto bypass arming
[
AWAY
]
+
MASTER CODE
OR
USER CODE
1, 2, 3
)
(System arming without the need to enter zone bypasses)
If you want to arm the system without manually entering zones to be
bypassed on the keypad, you can use the "Away" auto-bypass fea-
ture.
[
AWAY
]
+
MASTER CODE
or [
AWAY
] +
USER CODE
1
(
2
OR
3
) should
be keyed in. The control panel will automatically bypass any open
zones after the exit delay terminates and the system will be armed.
The "ready" light does not have to be on, but all open zones must be
"bypass-enabled". If any zones have been left open, the
[
BYP
]
light
will illuminate to indicate that zones have automatically been
bypassed. (
The fire zone cannot be bypassed
.) Please note: This
feature is not recommended for regular use because leaving zones
open can reduce the efficiency of system protection.
Panic Alarms
If you need to signal a "panic" situation, pressing keys
[1]
and
[3]
simultaneously for 1 second will generate a "panic" alarm. Panic
alarms will be recorded in memory but not displayed on the keypad.
7
6
UM727
UM727