To reprogram the timer, press
[
ENTER
]
, followed by the master
code/user code 1, and
[
MEM
]
. Key
[
MEM
]
flashes. Then enter 2
digits (00 to 23) for hours, followed by 2 digits (00 to 59) for min-
utes. Press
[
ENTER
]
.
Trouble 9
Tamper/zone wiring failure
Indicates that there is a wiring problem in a protected zone, the
LCD display reads “
TROUBLE
09
TAMPER
”.
Trouble 10
Telephone line monitor
If the panel detects telephone line loss, the LCD display reads
“
TROUBLE
10
PHONE LINE
”.
Trouble 11
Fire/trouble
If the fire zone is cut, fire zone key and trouble, the display will
read“
TROUBLE
11
FIRE LOOP
”.
Most "trouble" conditions will be programmed by your installer to
be reported directly to your security company. Please contact
your alarm company to ensure that repairs are immediately made
to your security system.
Fire Alarm Operation
-
Alarm
Upon a Fire Alarm, the bell/siren will operate in "pulse mode".
Silence/Reset
:
To silence/reset a fire alarm, enter a valid user code.
IMPORTANT: IN CASE OF FIRE, FOLLOW YOUR EVACUATION
PLAN IMMEDIATELY!
If there is no fire condition, contact your mon-
itoring company without delay to avoid an unnecessary response.
UM639
23
power supply is unable to charge the battery
and/or
the power
supply voltage exceeds 14.9 volts, the LCD display will read
“
TROUBLE
02
POWER SUPPLY
”. Power failure can be excluded from
[
TRBL
]
key display by your alarm installer.
Trouble 4
Bell disconnect
If a bell or siren is not connected to the bell/siren output, “
TROU
-
BLE
04
NO BELL
” appears in the display.
Trouble 5
Maximum bell current
If the processor recognizes that the bell/siren output current
exceeds 3A,. the LCD display reads “
TROUBLE
05
MAX BELL OUTPUT
”.
Automatic bell output shutdown results. Once the problem is cor-
rected, power will automatically be restored to the bell/siren circuit.
Trouble 6
Maximum auxiliary current
If the processor has recognized that the auxiliary output current
exceeds
1A
(748ES -
3A
), the LCD display will read “
TROUBLE
06
MAX AUX OUTPUT
”. This causes automatic shutdown of the auxiliary
output. Once the problem is corrected, power will automatically
be restored to the auxiliary output. This output powers such
devices as motion detectors and accessory modules.
Trouble 7
Communicator report failure
If your control panel cannot communicate with the central moni-
toring station, the LCD display reads “
TROUBLE
07
COMMUNICATION
”.
Trouble 8
Timer loss
If the system timer is not functioning, usually after a total battery
and AC power failure, the LCD display reads “
TROUBLE
08
TIMER
LOSS
”. The timer should be reprogrammed after total power loss.
UM639
22