background image

ACCESS CODES

N

4 digit

N

6 digit

Name

Code                           Arming Priority

Regular  Stay/A  Away/B   Byp

Master 00

N NN N

User 01

NNN N

User 02

NNN N

User 03

NNN N

User 04

NNN N

User 05

NNN N

User 06

NNN N

User 07

NNN N

User 08

NNN N

User 09

NNN N

User 10

NNN N

User 11

N NN N

User 12

NNN N

User 13

NNN N

User 14

NNN N

User 15

NNN N

User 16

NNN N

User 17

NNN N

User 18

NNN N

User 19

NNN N

User 20

NNN N

User 21

NNN N

User 22

NNN N

User 23

NNN N

User 24

NNN N

User 25

NNN N

ACCESS CODES

UM639

27

26

IMPORTANT: Keep this information in a secure location.

ZONE DESCRIPTION

PARTITIONING

N

Yes  

N

No          SYSTEM    24   Bypass

ACTIVATED

Stay/   Away/  Hr   Enabled

A         B

Zone   1:

N N N N

Zone   2:

N N N N

Zone   3:

N N N N

Zone   4:

N N N N

Zone   5:

N N N N

Zone   6:

N N N N

Zone   7:

N N N N

Zone   8:

N N N N

Zone   9:

N N N N

Zone   10:

N N N N

Zone   11:

N N N N

Zone   12:

N N N N

Zone   13:

N N N N

Zone   14:

N N N N

Zone   15:

N N N N

Zone   16:

N N N N

Zone   17:

N N N N

Zone   18:

N N N N

Zone   19:

N N N N

Zone   20:

N N N N

Zone   21:

N N N N

Zone   22:

N N N N

Zone   23:

N N N N

Zone   24:

N N N N

UM639

Summary of Contents for Esprit 639

Page 1: ...DE plus CODE Activates manual zone bypassing You select which zones to leave open when arming the system BYP plus CODE Used to scroll through information presented in display Press followed by or to s...

Page 2: ...The dwelling or building that you want to secure can be divided into as many as 24 zones depending upon which model of the ESPRIT panel you require and controlled by up to 5 keypads or PS1 bed side re...

Page 3: ...programmable delay set by the installer between each message If zone status is normal the LCD display will read SYS TEM READY If any zone are open the display will read ZONE OPEN The display automatic...

Page 4: ...too obvious such as your telephone number or street address or codes like 1234 since these codes are often used as defaults by many manufacturers Your installer will program the Esprit to accept 4 or...

Page 5: ...639 6 ize yourself with all 5 arming procedures so that you can take full advantage of your security system 1 REGULAR system arming used for normal day to day system operation The keypad s green READY...

Page 6: ...light is on pressing KEY 10 steadily for 2 sec onds automatically full arms the system if programmed No UM639 8 user code is required The display will read SYSTEM ARMED at the end of the exit delay Th...

Page 7: ...y zones that your installer has programmed bypass enabled can be UM639 10 bypassed during manual bypass arming normal arming or Stay arming Note that the fire zone cannot be bypassed Press the bypass...

Page 8: ...gen UM639 12 erate a panic Pressing keys 4 and 6 simultaneously for 2 seconds will generate a panic alarm or if programmed a med ical alarm Pressing keys 7 and 9 simultaneously for 2 sec onds will ge...

Page 9: ...m A Please note UM639 14 that if the system is in entry delay or if an alarm is in progress for your protection the panel can only be disarmed from a keypad Pressing any two PS1 keys simultaneously wi...

Page 10: ...st level programming The first message which will appear in the display will read CONTRAST ADJ 00 PRESS Press the or keys to increase or decrease the contrast until it reaches the level you require Wh...

Page 11: ...8 In programming mode when the CHIME MUTE message is dis played zones shown on the KEY ON line have the chime fea ture activated To turn on the chime zone feature press the cor responding key to activ...

Page 12: ...ing on battery power with no AC Trouble 2 Power failure If AC power is not being supplied to the control panel and or the UM639 21 ture continue pressing ENTER to scroll through the list Note Chime zo...

Page 13: ...or the power supply voltage exceeds 14 9 volts the LCD display will read TROUBLE 02 POWER SUPPLY Power failure can be excluded from TRBL key display by your alarm installer Trouble 4 Bell disconnect...

Page 14: ...e standby battery be changed every three years UM639 25 Fire Safety in the Home Reasonable fire safety can be achieved following a 3 point program 1 Minimizing fire hazards 2 Providing a fire warning...

Page 15: ...21 N N N N User 22 N N N N User 23 N N N N User 24 N N N N User 25 N N N N ACCESS CODES UM639 27 26 IMPORTANT Keep this information in a secure location ZONE DESCRIPTION PARTITIONING N Yes N No SYSTE...

Page 16: ...0 sec You have seconds to EXIT your premises Your Entry delay 1 is sec and you may enter thru zone Your Entry delay 2 is sec and you may enter thru zone Your Siren if activated by an alarm will sound...

Page 17: ...products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expre...

Reviews: