![background image](http://html2.mh-extra.com/html/paradox/envy-nvx80/envy-nvx80_installation-manual_3587762007.webp)
NVX80 Installation Manual
7
2.2 Installing the NVX80 Step-by-Step
Figure 1: NVX80 Back Cover Components
Mini Level
Wall Tamper
Terminal Block
Wall Mount
knock-out (1)
Corner Mount
knock-out (5)
Corner Mount
knock-out (6)
Captive Screw
(and Cover Tamper)
2
3
4
5
6
7
8
9
Right Wall Tamper
knock-out (4)
Wall Mount
knock-out (3)
Right
Corner Tamper
knock-out (9)
Corner Mount
knock-out (8)
Tamper screw
1
Wall Mount
knock-out (2)
Corner Mount
knock-out (7)
*Left Wall Tamper
knock-out (11)
*Left Corner Tamper
knock-out (10)
10
11
1. Loosen the captive screw located at the bottom of the unit.
2. Separate the back cover from the front of the NVX80 by carefully sliding it up and off.
3. Prepare the back cover for a wall-mount installation by drilling out the appropriate knock-out holes (see Figure 1).
for
Wall
Installations: drill holes #1, 2 and 3, and wall tamper 4.
for
Corner
Installations: drill holes #5, 6, 7, 8 and wall tamper 9.
Note:
The wall tamper can be relocated to the left side of the unit, if desired. Simply remove the retaining screw,
place the tamper in its corresponding spot on the left, and refasten the retaining screw. Make sure the two black
wires remain properly inserted into the (B-) and (TMP) contacts on the power block. For left-sided wall tampers, the
following knock out holes are used:
for
Wall
Installations: drill holes #1, 2 and 3, and wall tamper 11.
for
Corner
Installations: drill holes #5, 6, 7, 8 and wall tamper 10.
4. Mark the selected location using the back cover of the unit as a template. With the help from the level on the back
cover, align your unit accordingly.
5. Remove the back cover and drill the marked holes into the wall surface.
6. Install wall anchors for added support. (Consider the material being drilled.)
7. Pass electrical wires through the opening on the back cover. Secure the back cover of the unit to the wall surface
using the appropriate mounting screws. Re-level if necessary before securing.