22
NVX80 Installation Manual
4.2 MW Anti-Mask Indications
The MW anti-mask is activated if a validated detection of movement (both PIR and MW) has occurred, followed within the next 90n
seconds by a close MW detection without a PIR detection. This will cause the green frame to appear on the OLED screen for 90
seconds. The MW anti-mask relay has not yet been activated. If an alarm is triggered as the result of the main lens’ detection of an
object, during that same period, the blue frame will disappear and a MW anti-mask event will not occur. If no alarm is triggered by
detection of the main lens in the 90 second period, a MW anti-mask relay will be activated and the MW anti-mask logo will be
displayed. The MW anti-mask relay and logo will be cleared by an Alarm event triggered by the main lens.
An Active IR anti-mask has a higher display priority. If Active IR and MW anti-mask events occur simultaneously, then the blue frame
will appear instead of a green frame and the Active IR anti-mask logo will appear instead of the MW anti-mask logo. The resulting
relays are not affected by the display priority.
MW anti-mask detection appears in Operational Mode after detection of a moving
object and 90 seconds have elapsed from the time the MW anti-mask Notification
was displayed. In test mode, MW anti-mask detection appears immediately on
detection of a moving object.
MW anti-mask notification appears in Operational mode only, immediately on
detection of a moving object for 90 seconds.
4.3 PIR and MW Indications
4.3.1 Pre-Alarms
When a movement signal is detected by within a PIR or MW range, the corresponding pre-alarm is shown.
The detector waits for 16 seconds for the complementary technology’s detection. If no additional movement is detected during
that time, the detector will return to its standby state.
PIR Pre-Alarm in Test Mode
PIR Pre-Alarm in Operation Mode
MW Pre-Alarm in Test Mode