36
PROGRAMMING GUIDE
CONTACT ID REPORT CODE LIST
If using the Ademco Contact ID format, key in the 2-digit hexadecimal value (PROG. VALUE) to program the desired report
codes into sections
[600]
to
[718]
.
CID#
Reporting
Prog.
Code
Value
CID#
Reporting
Prog.
Code
Value
CID#
Reporting
Prog.
Code
Value
MEDICAL ALARMS - 100
204
Low Water Level
2F
403
Automatic O/C
5D
100
Medical Alarm
01
205
Pump Activated
30
404
Late to O/C
5E
101
Pendant Transmitter
02
206
Pump Failure
31
405
Deferred
5F
102
Fail to Report In
03
SYSTEM TROUBLES - 300 & 310
406
Cancel
60
FIRE ALARMS - 110
300
System Trouble
32
407
Remote Arm/Disarm
61
110
Fire Alarm
04
301
AC Loss
33
408
Quick Arm
62
111
Smoke
05
302
Low System Battery
34
409
Keyswitch O/C
63
112
Combustion
06
303
RAM Checksum Bad
35
REMOTE ACCESS - 410
113
Water Flow
07
304
ROM Checksum Bad
36
411
Callback Request Made
64
114
Heat
08
305
System Reset
37
412
Success - Download Access
65
115
Pull Station
09
306
Panel Program Changed
38
413
Unsuccessful Access
66
116
Duct
0A
307
Self-Test Failure
39
414
System Shutdown
67
117
Flame
0B
308
System Shutdown
3A
415
Dialer Shutdown
68
118
Near Alarm
0C
309
Battery Test Failure
3B
ACCESS CONTROL - 420
PANIC ALARMS - 120
310
Ground Fault
3C
421
Access Denied
69
120
Panic Alarm
0D
SOUNDER/RELAY TROUBLES - 320
422
Access Report By User
6A
121
Duress
0E
320
Sounder Relay
3D
SOUNDER RELAY DISABLES - 520
122
Silent
0F
321
Bell 1
3E
520
Sounder/Relay Disabled
6B
123
Audible
10
322
Bell 2
3F
521
Bell 1 Disable
6C
BURGLAR ALARMS - 130
323
Alarm Relay
40
522
Bell 2 Disable
6D
130
Burglary
11
324
Trouble Relay
41
523
Alarm Relay Disable
6E
131
Perimeter
12
325
Reversing
42
524
Trouble Relay Disable
6F
132
Interior
13
SYSTEM PERIPHERAL TROUBLES - 330 & 340
525
Reversing Relay Disable
70
133
24-Hour
14
330
System Peripheral
43
COMMUNICATION DISABLES - 550 & 560
134
Entry/Exit
15
331
Polling Loop Open
44
551
Dialer Disabled
71
135
Day/Night
16
332
Polling Loop Short
45
552
Radio xmitter Disabled
72
136
Outdoor
17
333
Exp. Module Failure
46
BYPASSES - 570
137
Tamper
18
334
Repeater Failure
47
570
Zone Bypass
73
138
Near Alarm
19
335
Local Printer Paper Out
48
571
Fire Bypass
74
GENERAL ALARMS - 140
336
Local Printer Failure
49
572
24-Hour Zone Bypass
75
140
General Alarm
1A
COMMUNICATION TROUBLES - 350 & 360
573
Burg. Bypass
76
141
Polling Loop Open
1B
350
Communication
4A
574
Group Bypass
77
142
Polling Loop Short
1C
351
Telco Fault 1
4B
TEST/MISC. - 600
143
Expansion Module Failure
1D
352
Telco Fault 2
4C
601
Manual Trigger Test
78
144
Sensor Tamper
1E
353
Long Range Radio
4D
602
Periodic Test Report
79
145
Expansion Module Tamper
1F
354
Fail to Communicate
4E
603
Periodic RF Xmission
7A
24-HOUR NON-BURGLARY - 150 & 160
355
Loss of Radio Supervision
4F
604
Fire Test
7B
150
24-Hour Non-Burglary
20
356
Loss of Central Polling
50
605
Status Report to Follow
7C
151
Gas Detected
21
PROTECTION LOOP TROUBLES - 370
606
Listen-in to Follow
7D
152
Refrigeration
22
370
Protection Loop
51
607
Walk Test Mode
7E
153
Loss of Heat
23
371
Protection Loop Open
52
621
Event Log Reset
7F
154
Water Leakage
24
372
Protection Loop short
53
622
Event Log 50% Full
80
155
Foil Break
25
373
Fire Trouble
54
623
Event Log 90% Full
81
156
Day Trouble
26
SENSOR TROUBLES - 380
624
Event Log Overflow
82
157
Low Bottled Gas Level
27
380
Sensor Trouble
55
625
Time/Date Reset
83
158
High Temp
28
381
Loss of Super. -RF
56
626
Time/Date Inaccurate
84
159
Low Temp
29
382
Loss of Super. - RPM
57
627
Program Mode Entry
85
161
Loss of Air Flow
2A
383
Sensor Tamper
58
628
Program Mode Exit
86
FIRE SUPERVISORY - 200 & 210
384
RF xmtr. Low Battery
59
631
Exception Schedule Change
87
200
Fire Supervisory
2B
OPEN/CLOSE - 400
201
Low Water Pressure
2C
400
Open/Close
5A
202
Low CO2
2D
401
O/C by User
5B
203
Gate Valve Sensor
2E
402
Group O/C
5C
Summary of Contents for Digiplex V2.14
Page 1: ...Digiplex System V2 14 V2 2ACC Control Panel Programming Guide...
Page 2: ......
Page 42: ...40 PROGRAMMING GUIDE Hardware Connections SINGLE ZONE INPUTS ATZ DOUBLE ZONE INPUTS...
Page 43: ...DIGIPLEX SERIES 41 CONNECTING A ZX4 EXPANDER MODULE FIRE ZONE KEYSWITCH AND PGM CONNECTIONS...
Page 44: ...42 PROGRAMMING GUIDE DIGIPLEX PCB LAYOUT...
Page 47: ......
Page 48: ......