DIGIPLEX SERIES
19
Partition 3: Options
Bold
= Default setting
SECTION
[513]
: Partition 3 Options
Option
OFF
ON
[1]
Partition 3 arms & disarms with Partition 1
l
Disabled
l
Enabled
[2]
Partition 3 arms & disarms with Partition 2
l
Disabled
l
Enabled
[3]
Switch to Stay Arming (if no delay zone opened)
l
Disabled
l
Enabled
[4]
Partition 3 arms & disarms with Partition 4
l
Disabled
l
Enabled
[5]
Timed Auto-Arming
l
Disabled
l
Enabled
[6]
“No Movement” Auto-Arming
l
Disabled
l
Enabled
[7]
Arming method for auto arming
l
Force Arming
l
Stay Arming
[8]
Exit Delay termination
l
Disabled
l
Enabled
SECTION
[514]
: Partition 3 Options
Option
OFF
ON
[1]
Panic 1 (keys [1] and [3])
l
Disabled
l
Enabled
[2]
Panic 2 (keys [4] and [6])
l
Disabled
l
Enabled
[3]
Panic 3 (keys [7] and [9])
l
Disabled
l
Enabled
[4]
Panic 1 alarm type
l
Report Only
l
Audible Alarm
[5]
Panic 2 alarm type
l
Report Only
l
Audible Alarm
[6]
Panic 3 alarm type
l
Report Only
l
Fire Alarm
[7]
Report Disarming Options
l
Always report disarming
l
Report disarming only after alarm
[8]
Future Use
l
N/A
l
N/A
SECTION
[515]
: Partition 3 Options
Option
OFF
ON
[1]
Bell Squawk upon Disarming
l
Disabled
l
Enabled
[2]
Bell Squawk upon Arming
l
Disabled
l
Enabled
[3]
Bell Squawk upon Auto-Arming
l
Disabled
l
Enabled
[4]
Bell Squawk during Exit Delay
l
Disabled
l
Enabled
[5]
Bell Squawk during Entry Delay
l
Disabled
l
Enabled
[6]
Bell Squawk upon Remote Arming/Disarming
l
Disabled
l
Enabled
[7]
Ring Back: bell squawk if disarmed after alarm
l
Disabled
l
Enabled
[8]
Ring Back: keypad beeps if disarmed after alarm
l
Disabled
l
Enabled
SECTION
[516]
: Partition 3 Options
Option
OFF
ON
[1]
One-Touch Regular Arming
l
Disabled
l
Enabled
[2]
One-Touch Stay Arming
l
Disabled
l
Enabled
[3]
One-Touch Instant Arming
l
Disabled
l
Enabled
[4]
One-Touch Force Arming
l
Disabled
l
Enabled
[5]
One-Touch Stay or Instant Disarming
l
Disabled
l
Enabled
[6]
One-Touch Bypass Programming
l
Disabled
l
Enabled
[7]
One-Touch Event Display
l
Disabled
l
Enabled
[8]
No Exit Delay when arming with remote control
l
Disabled
l
Enabled
Summary of Contents for Digiplex V2.14
Page 1: ...Digiplex System V2 14 V2 2ACC Control Panel Programming Guide...
Page 2: ......
Page 42: ...40 PROGRAMMING GUIDE Hardware Connections SINGLE ZONE INPUTS ATZ DOUBLE ZONE INPUTS...
Page 43: ...DIGIPLEX SERIES 41 CONNECTING A ZX4 EXPANDER MODULE FIRE ZONE KEYSWITCH AND PGM CONNECTIONS...
Page 44: ...42 PROGRAMMING GUIDE DIGIPLEX PCB LAYOUT...
Page 47: ......
Page 48: ......