![background image](http://html1.mh-extra.com/html/paradox/digiplex-evo-apr-prt3/digiplex-evo-apr-prt3_programming-instructions-manual_3610974019.webp)
18
034
Zone Tamper Restore
0-096
Zone Numbers
001-008
035
Special Tamper
000
Keypad Lockout
001-008
036
Trouble Event
000
TLM Trouble
000-008
001
AC Failure
002
Battery Failure
003
Auxiliary Current Limit
004
Bell Current Limit
005
Bell Absent
006
Clock Trouble
007
Global Fire Loop
037
Trouble Restore
000
TLM Trouble
000-008
001
AC Failure
002
Battery Failure
003
Auxiliary Current Limit
004
Bell Current Limit
005
Bell Absent
006
Clock Trouble
007
Global Fire Loop
038
Module Trouble
000
Combus Fault
000-008
001
Module Tamper
002
ROM/RAM error
003
TLM Trouble
004
Fail to Communicate
005
Printer Fault
006
AC Failure
007
Battery Failure
008
Auxiliary Failure
039
Module Trouble Restore
000
Combus Fault
000-008
001
Module Tamper
002
ROM/RAM error
003
TLM Trouble
004
Fail to Communicate
005
Printer Fault
006
AC Failure
007
Battery Failure
008
Auxiliary Failure
040
Fail to Communicate on
telephone Number
001-004
Telephone Number
000-008
041
Low Battery on Zone
001-096
Zone Numbers
001-008
042
Zone Supervision Trouble
001-096
Zone Numbers
001-008
043
Low Battery on Zone
Restored
001-096
Zone Numbers
001-008
044
Zone Supervision Trouble
Restored
001-096
Zone Numbers
001-008
Event
Group (G)
Event Group Description
Event Number (N)
Event Number Description
Area Number (A)