Digiplex DGP-NE96
- 29 -
Programming Guide
Keypad Numbering
Sections
[2801]
to
[2832]
are used solely for the purpose of identifying a keypad in the event buffer. Enter the 8-digit serial number of the keypad you wish to
label as keypad x (1 to 32). The event buffer will then display any events pertaining to a keypad as keypad 1 or keypad 2, etc.
Control Panel Settings
System Options
= Default setting
* Please note that when the Combus Speed is changed, all operations on the system will be suspended for approximately 1 minute while
the system configures itself.
†
A 40VA transformer is required when selecting the 850mA battery charge current. Using a 20VA transformer with a battery charge
current of 850mA may damage the system.
Section
Keypad #
Serial Number
Section
Keypad #
Serial Number
Section
Keypad #
Serial Number
[2801]
Keypad 1
__/__/__/__/__/__/__/__
[2812]
Keypad 12 __/__/__/__/__/__/__/__
[2823]
Keypad 23 __/__/__/__/__/__/__/__
[2802]
Keypad 2
__/__/__/__/__/__/__/__
[2813]
Keypad 13 __/__/__/__/__/__/__/__
[2824]
Keypad 24 __/__/__/__/__/__/__/__
[2803]
Keypad 3
__/__/__/__/__/__/__/__
[2814]
Keypad 14 __/__/__/__/__/__/__/__
[2825]
Keypad 25 __/__/__/__/__/__/__/__
[2804]
Keypad 4
__/__/__/__/__/__/__/__
[2815]
Keypad 15 __/__/__/__/__/__/__/__
[2826]
Keypad 26 __/__/__/__/__/__/__/__
[2805]
Keypad 5
__/__/__/__/__/__/__/__
[2816]
Keypad 16 __/__/__/__/__/__/__/__
[2827]
Keypad 27 __/__/__/__/__/__/__/__
[2806]
Keypad 6
__/__/__/__/__/__/__/__
[2817]
Keypad 17 __/__/__/__/__/__/__/__
[2828]
Keypad 28 __/__/__/__/__/__/__/__
[2807]
Keypad 7
__/__/__/__/__/__/__/__
[2818]
Keypad 18 __/__/__/__/__/__/__/__
[2829]
Keypad 29 __/__/__/__/__/__/__/__
[2808]
Keypad 8
__/__/__/__/__/__/__/__
[2819]
Keypad 19 __/__/__/__/__/__/__/__
[2830]
Keypad 30 __/__/__/__/__/__/__/__
[2809]
Keypad 9
__/__/__/__/__/__/__/__
[2820]
Keypad 20 __/__/__/__/__/__/__/__
[2831]
Keypad 31 __/__/__/__/__/__/__/__
[2810]
Keypad 10 __/__/__/__/__/__/__/__
[2821]
Keypad 21 __/__/__/__/__/__/__/__
[2832]
Keypad 32 __/__/__/__/__/__/__/__
[2811]
Keypad 11 __/__/__/__/__/__/__/__
[2822]
Keypad 22 __/__/__/__/__/__/__/__
Section
Data
Description
Default
[3001]
__/__/__ (147 = Locked, 000 = Unlocked)
I
NSTALLER
LOCK
000
[3010]
__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ PC
PHONE
NUMBER
(32 D
IGITS
)
[3011]
__/__/__/__
P
ANEL
IDENTIFICATION
0000
[3012]
__/__/__/__
PC
PASSWORD
0000
[3020]
__/__
P
ANEL
PARTITION
(00 - 08)
00
[3021]
__/__
T
ROUBLE
SHUTDOWN
(00 - 15)
00
SECTION [3030] : System Options 1
SECTION [3031] : Partition Options 1
Option
OFF
ON
Option
OFF
ON
[1]
PGM 1 = 2-wire smoke detector
input (255)
Disabled
N
Enabled
[1]
Partition 1
N
Disabled
Enabled
[2]
No bell cut-off during fire alarm
Disabled
N
Enabled
[2]
Partition 2
Disabled
N
Enabled
[3]
Daylight saving time
N
Disabled
Enabled
[3]
Partition 3
Disabled
N
Enabled
[4]
Shabbat feature
Disabled
N
Enabled
[4]
Partition 4
Disabled
N
Enabled
[5]
Battery charge current
350mA
N
850mA
†
[5]
Partition 5
Disabled
N
Enabled
[6]
AC failure not displayed as trouble
Disabled
N
Enabled
[6]
Partition 6
Disabled
N
Enabled
[7]
Clear bell limit trouble
On restore
N
Manually
[7]
Partition 7
Disabled
N
Enabled
[8]
Combus Speed*
Normal
N
High
[8]
Partition 8
Disabled
N
Enabled