Digiplex DGP-NE96
- 37
-
Programming Guide
Partition Panic Alarm Options
Partition Bell Squawk Options
Partition One-Touch Options
* If a keypad is assigned to more than one partition, the one-touch feature must be enabled in all the keypad’s assigned partitions. Example: To enable the one-touch Regular Arming
feature of a keypad assigned to partitions 1, 2 and 5, enable sections [3125] option [1], [3225] option [1] and [3525] option [1].
Partition 1
[3123]
Partition 2
[3223]
Partition 3
[3323]
Partition 4
[3423]
Partition 5
[3523]
Partition 6
[3623]
Partition 7
[3723]
Partition 8
[3823]
Option
(
= Default Setting)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
[1]
Panic 1 (Keys 1 & 3)
N
N
N
N
N
N
N
N
[2]
Panic 2 (Keys 4 & 6)
N
N
N
N
N
N
N
N
[3]
Panic 3 (Keys 7 & 9)
N
N
N
N
N
N
N
N
[4]
Panic 1 Alarm Type
(
OFF
= Report Only;
ON
= Audible Alarm)
N
N
N
N
N
N
N
N
[5]
Panic 2 Alarm Type
(
OFF
= Report Only;
ON
= Audible Alarm)
N
N
N
N
N
N
N
N
[6]
Panic 3 Alarm Type
(
OFF
= Report Only;
ON
= Fire Alarm)
N
N
N
N
N
N
N
N
[7]
Report Disarming Options
(
OFF
= Always;
ON
= Only After Alarm)
N
N
N
N
N
N
N
N
[8]
Always Force Arm when Regular Arming
N
N
N
N
N
N
N
N
Partition 1
[3124]
Partition 2
[3224]
Partition 3
[3324]
Partition 4
[3424]
Partition 5
[3524]
Partition 6
[3624]
Partition 7
[3724]
Partition 8
[3824]
Option
(
= Default Setting)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
[1]
Bell Squawk upon Disarming
N
N
N
N
N
N
N
N
[2]
Bell Squawk upon Arming
N
N
N
N
N
N
N
N
[3]
Bell Squawk upon Auto-arming
N
N
N
N
N
N
N
N
[4]
Bell Squawk during Exit Delay
N
N
N
N
N
N
N
N
[5]
Bell Squawk during Entry Delay
N
N
N
N
N
N
N
N
[6]
Bell Squawk upon Remote Arming/Disarming
N
N
N
N
N
N
N
N
[7]
Ring Back: Bell Squawk if Disarmed after Alarm
N
N
N
N
N
N
N
N
[8]
Ring Back: Keypad beeps if Disarmed after Alarm
N
N
N
N
N
N
N
N
Partition 1
[3125]
Partition 2
[3225]
Partition 3
[3325]
Partition 4
[3425]
Partition 5
[3525]
Partition 6
[3625]
Partition 7
[3725]
Partition 8
[3825]
Option
(
= Default Setting)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
[1]
One-touch Regular Arming
*
N
N
N
N
N
N
N
N
[2]
One-touch Stay Arming
*
N
N
N
N
N
N
N
N
[3]
One-touch Instant Arming
*
N
N
N
N
N
N
N
N
[4]
One-touch Force Arming
*
N
N
N
N
N
N
N
N
[5]
One-touch Stay or Instant Disarming
*
N
N
N
N
N
N
N
N
[6]
One-touch Bypass Programming
*
N
N
N
N
N
N
N
N
[7]
One-touch Event Display
*
N
N
N
N
N
N
N
N
[8]
No Exit Delay when Arming with remote control
N
N
N
N
N
N
N
N