37
Configuring PIR Settings
Configuring PIR Settings with Keypads
To configure PIR settings with Keypads:
1.
Press and hold the [
0
] key.
The Installer Code screen opens in the LCD prompting to enter an Installer Code.
2.
Enter your
Installer Code
.
The Section screen opens.
Note:
The default installer code is
000000
.
3.
Key- in [
4003
].
The Module Programming screen opens.
4.
Key-in the HD77 camera
Serial Number
.
The Module Section screen opens.
5.
Configure
PIR LED Display
settings:
a.
Key-in Section [
001
].
The 001 Module Data screen opens.
b.
Key-in the value
1
(On) to display the LED #3 red indicator when PIR motion is detected
OR
:
Do not enter a value. The PIR LED Display indicator will not light up when PIR motion is detected.
Note:
•
The
default
PIR LED Display value is
1
(
On
).
•
Do not configure Options 2 - 8
c.
Select Enter.
The 002 Module Data screen (sensitivity levels) opens.
6.
Configure PIR
Sensitivity Level
settings:
a.
Key-in Section [
002
].
b.
Select the required PIR sensitivity level value: between
000
-
004
with the up/down arrows.
Note:
The
default
PIR sensitivity level is
002
.
c.
Select Enter.
The 003 Module Data screen (security levels) opens.
7.
Configure PIR
Security Level
settings:
a.
Key-in Section [
003
].
b.
Select the required PIR security level value between
0-2
with the up/down arrows.
Note:
The
default
PIR security level is
0
.
c.
Select Enter save the settings.
The PIR settings are configured.
Summary of Contents for HD77
Page 1: ......
Page 4: ...4 ...
Page 18: ...Mounting the HD77 18 Mounting the HD77 Camera on a Wall or Corner ...
Page 40: ...Verifying HD77 Camera Functionality 40 Configuring PIR Settings with Keypads ...
Page 44: ...Deleting a HD77 Camera from ParadoxMyHome 44 ...
Page 46: ...46 Figure 3 BabyWare Home Window ...
Page 50: ...50 ...
Page 54: ...54 ...
Page 68: ...68 ...