HSL-32 Hibachi Griddle Operator Manual
Troubleshooting
•
41
Figure 28 Adjust Air Gap
2.
Confirm the air shutter is set to the appropriate opening – 1/8” for natural gas, 3/8” for LP gas
3.
Make small changes to adjust the shutter position
a.
Loosen setscrew
b.
More open to allow more air to decrease the flame size
c.
Less open to allow less air to increase the flame size
d.
Tighten the setscrew
4.
Re-install the burner(s), test the flame, and adjust again as needed
5.
Repeat for all burners as needed
Convert to Another Gas Type
The conversion process (orifice change-out) is the same for each gas. Whatever gas your griddle is set up for,
it is supplied with a conversion kit (Figure 29 left) to allow changeover to the other fuel type. The customer
must provide the required LP gas inlet or NG regulator (4” water column, 1/2" ports).
Figure 29 Gas Conversion Kit
This procedure must be completed by a licensed plumber or gas professional.
1.
Shut off and disconnect the gas source from the griddle
2.
Remove griddle plate to expose the main burners