HSL-32 Hibachi Griddle Operator Manual
Connect Griddle to Gas Source
•
29
Perform a leak test before first use, and at least once a year whether the LP gas supply cylinder has been
disconnected or not, whenever the gas cylinder is connected to the regulator, and whenever any part of the
gas system is disconnected or replaced
The leak test should check all joints of the gas delivery system for both NG and LP gas systems:
Figure 23 Leak Test All Gas Joints
Complete this procedure to leak test the griddle and gas connections:
1.
Mix a solution of soapy water in a spray bottle using one part liquid soap to two parts water
2.
Ensure all the griddle control knobs are in the OFF position. Turn on the gas:
•
On NG systems, turn on the main feed valve to the griddle
•
On LP systems, turn the cylinder valve knob counterclockwise one turn to open
3.
Spray the soapy water solution on all joints of the gas delivery system (Figure 24)
Figure 24 Leak Test Spray and Bubbles
4.
If bubbles appear and/or grow, turn the gas source OFF, remove, reconnect and tighten the
connection, and re-test
5.
To leak test the burner orifices, remove the griddle plate and burners per the
procedure on page 20