On LP systems, turn the cylinder valve knob counterclockwise one turn to open
3.
Spray the soapy water solution on all joints of the gas delivery system (Figure 21)
Figure 21 Leak Test Spray and Bubbles
4.
If bubbles appear and/or grow, turn the gas source OFF, remove, reconnect and tighten the
connection, and re-test
5.
To leak test the burner orifices, remove the grate and burners per the Convert to Another Gas Type
procedure on page 36
6.
Looking below the burners (Figure 22), spray each orifice with soapy water to check for bubbles
Figure 22 Burner Orifice Leak Test
7.
Make note of the location of any leaks indicated by growing bubbles and turn off the gas supply
8.
Contact a qualified gas technician to tighten any loose connections or replace any faulty parts
9.
Repeat the leak check as needed; when there are no more leaks, wipe away the soap solution
10.
Replace the burners and grate and proceed
11.
Do not use the burner unit until all leaks are resolved