GSL-SB2B Double Side Burner Operator Manual
Connect Double Burner to Gas Source
•
27
7.
If the cylinder connection cannot be completed, disconnect the regulator and try again; if the
connection still cannot be made, do not use this regulator and obtain a replacement regulator
8.
To disconnect the LP gas tank, turn off the main cylinder valve; rotate the black coupling nut
counterclockwise until disengaged
Leak Test
Never use a lighted match or other open flame to check for leaks.
Do not smoke or allow other sources of ignition in the area while doing
a leak test.
Do not attempt to repair an LP cylinder valve if it is damaged. The
cylinder must be returned to a proper LP tank supplier and replaced.
Always conduct the leak test outdoors in a well-ventilated area.
Perform a leak test before first use, and at least once a year whether the LP gas supply cylinder has been
disconnected or not, whenever the gas cylinder is connected to the regulator, and whenever any part of the
gas system is disconnected or replaced.
The leak test should check all joints of the gas delivery system for both NG and LP gas systems:
Figure 20 Leak Test All Gas Joints
Complete this procedure to leak test the burner unit and gas connections:
1.
Mix a solution of soapy water in a spray bottle using one part liquid soap to two parts water
2.
Ensure all the burner unit control knobs are in the OFF position. Turn on the gas:
•
On NG systems, turn on the main feed valve to the burner unit