P300H
P300 Series Modem Installation and Operating Handbook
Page 134
6.20.1 Service, USER PARAMETERS Menu
User: 1:Lock Kbd 2:Clr Cfg
3:Clr All+Reset 4:Fan [Auto]
Service, User Parameters Menu
The options are:
ÔÑÝÕ ÕÞÜ
This locks the keyboard after displaying a screen showing the unlock code. As
with all Paradise equipment the unlock code is simply the product number (eg
300). The unlock code is displayed before the keyboard is locked on the
Modem, as we had quite a few calls to the technical support line which start off
“
I ve just selected Lock Keyboard from the menu and ......
”
ÝÔÎ ÝÑÒÚ×Ù
This clears the current configuration down to its default blank state.
ÝÔÎ ßÔÔõÎÛÍÛÌ
This clears the entire non volatile memory, including current configuration, all
configuration memories, and the traffic log, then resets the processor.
ÚßÒ
Normally the fan is temperature controlled, switching on at 26C and off at 24C.
The internal temperature can be monitored on the
ÌÛÍÌô ÐÍË õ ÌÛÓÐ
menu. A
Unit Warning /deferred alarm will be activated if ever the internal temperature
reaches within 3 degrees Centigrade of the operating limits of 0C and 60C.
Should the internal temperature exceed the limits of 0C and 60C, then a Unit
Fault / Prompt Alarm is activated.
The Tx carrier is muted outside the
operating temperature range.
6.20.2 Service, FACTORY PARAMETERS Menu
Factory: 1:Serial# [01564] 2:Debug [0]
3:RemCont [Giveaway-120s] 4:Watchdog
Service, Factory Parameters Menu
The options are:
ÍÛÎ×ßÔ ý
This menu allows the serial number to be both viewed and edited.
ÜÛÞËÙ
Used for Paradise internal procedures only.
Setting Debug to a value other
than 0 is very likely to slow down the operation of the unit.
ÎÛÓ ÓúÝ
This option is used to set the timeout required before local control can be taken
if the unit is in remote mode. This is covered extensively in section Change,
Rem-M&C Menu on page 102
ÉßÌÝØÜÑÙ
This provides an option to test the watchdog timer. The watchdog timer is a
timer, which is regularly reset by the processor. Should it ever reach its set
time, then the processor has failed to reset it, and probably crashed.
Testing
the Watchdog timer therefore will cause the unit to reset, and corrupt
both Tx and Rx traffic for a few seconds.