P300H
P300 Series Modem Installation and Operating Handbook
Page 122
When
YES
is pressed with a non-zero value for the Autolog period, the following screen is accessed:
Autolog(Y/N): 1 Buffer % (Y) 2 Eb/No (Y)
3 Rx User BER (N) More
Log Autolog, Measurements Menu (1)
This screen allows the operator to toggle each of the first three loggable events on and off. (N) indicates
No, the data will not be logged, (Y) indicates Yes the data will be logged. Pressing the key
corresponding to each data type toggles between (Y) and (N). More options are available on subsequent
screens:
Autolog (Y/N): 1:BERT BER (N) Back
2:Tx Terr BER (N) 3:Rx Terr BER (N) More
Log Autolog, Measurements Menu (2)
Finally, if AUPC is active (see AUPC in section 8.11 on page 156), another subsequent screen is
offered:
Autolog (Y/N): 1:AUPC Delta Power (Y)
2:Distant end Eb/No (N) Back
Log Autolog, Measurements Menu (3:AUPC)