BA_PH_680-200_EN_11-22.docx
72
Figure 111: Error message 17
Message:
Auto EPS - Unexpected Error
Cause:
Communication with controller board A2 disturbed.
Remedy:
Check controller board A2 and replace if necessary.
Figure 112: Error message 18
Message:
Communication error with the fault indication module!
Cause:
Communication with monitoring PLC “A3“ is disturbed.
Remedy:
Check PLC module “A3” and replace if necessary.
If you are unable to correct a fault using our instructions, or if the fault occurs repeatedly after you have cor-
rected it, please call our customer service department on 0049 7571 / 755 - 0.
20.3
Retightening / Changing the V-belt
Before starting work, the main switch must be switched off and secured with a padlock
against being switched on again unexpectedly.
Figure 113: V-belt tightness
Procedure:
•
First flip the lever (
H
) to release
the tension of the V-belt.
•
Then loosen the lock nut (
K
)
•
Turn nut (
M
) slightly downwards
•
Tighten lock nut (
K
) again and flip
lever (
H
) again to tighten the belt
The belt is correctly tensioned when it can be
pushed through approx. 10 mm between the belt
pulleys at a lateral pressure of approx. 2 kg.
V-belts used:
Machine with manual V-belt shifting
5.5/7.5 kW / PK x 1000
H
K
M