BA_PH_680-200_EN_11-22.docx
71
Figure 105: Error message 11
Message:
Scoring saw cannot be started! Check riving knife.
Cause:
Riving knife switch S1 actuated.
Remedy:
•
Adjust the riving knife correctly.
•
Use a smaller saw blade and readjust the riving knife.
Figure 106: Error message 12
Message:
Calibration currently not possible!
Cause:
An attempt was made to calibrate with the saw blade
running.
Remedy:
Stop the main saw and wait until the saw blade has come
to a standstill, then start the calibration procedure again.
Figure 107: Error message 13
Message:
Positioning of the scoring saw not possible!
Calibrate scoring saw.
Cause:
•
Incorrect calibration value of the axis controller.
•
Calibration procedure was not carried out properly
last time.
•
New axis controller A2 installed and not yet calibrated.
Remedy:
Perform calibration procedure (again).
Figure 108: Error message 14
Message:
“Error” with yellow background in the speed window
.
Cause:
•
Position of the V-belt cannot be determined.
•
Speed fork B7 defective.
•
Main saw V-belt broken.
Remedy:
•
Check V-belt position.
•
Check speed fork B7 and replace if necessary.
•
Fit new V-belt.
Figure 109: Error message 15
Message:
General Modbus Error!
Cause:
Communication to the controller boards was disturbed
or the data could not be processed.
Remedy:
•
Check bus cable in the control cabinet.
•
Check network switch A5.
•
Check bus devices
(LEDs on network sockets of the units).
Figure 110: Error message 16
Message:
Modbus I/O exception!
Cause:
A bus participant transmits faulty values.
Remedy:
Restart machine.