BA_PH_680-200_EN_11-22.docx
32
8
Electrical Connection
The electrical connection must be carried out by an authorised electrician!
The electrical circuit diagrams are located in the control cabinet.
Please observe the specified nominal voltage 400 VAC / 50 Hz (3 phases / N / PE)!
Figure 16: Electrical connection
Connection to the mains (3 phases) is made at the terminal strip in
the terminal box. The 3 phases are to be connected to the terminals
“
L1
”, “
L2
”, and “
L3
”. The protective earth wire (yellow/green) must
be connected to the terminal marked “
PE
”
.
With optional machine socket, the neutral conductor must be con-
nected to the terminal marked
“
N
”
( please note:
“
N
”
is loaded!).
Then close the cable gland so that it is dust-tight again.
Observe the rotational direction of the saw blade!
If the rotational direction of the saw blade is wrong,
two outer conductors must be interchanged.
Correct direction of rotation of the saw blade:
Clockwise (when viewed from the front).
8.1
Back-up Fuses (On-site)
Motor Power
5.5 kW
7.5 kW
The fault loop impedance and the suitability of
the overcurrent protection device must be
checked at the installation site of the machine.
400 Volt
25 A
32 A or 35 A
Supply cable:
Cu, 5-wire.
The cross-section must be determined on site by a qualified electrician!
The regulations of the local electric power company apply!