21
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
System Settings
Display Auto Power On - When enabled, the unit will send a programmed command to the
display to turn on after detecting an A/V signal
Display Auto Power Off - When enabled, the unit will send a command to the display to turn off
after not detecting an A/V signal
Power Button Lock - Locks the front panel power button while Auto Power On/Off are
enabled.
Lamp Cool Down Timer
(10-300)
- Used with a projector whose lamp cannot be turned on for up
to 5 minutes after being shut off. Match settings with lamp delay on projector
Auto Power Off Timer
(10-240)
- Sets the period of time between the loss of A/V signal and when
the “Display Off” command is sent
Note:
LED will blink red for the auto power off time period then go solid
Note:
All functionality remains, only the HDBaseT output is turned off
Display Warm Up Timer
(10-300)
- Sets the period of time after the display is turned on, that the
power button will be locked
Note:
LED will blink green for the warm up timer period and then stay solid
Note:
When timers are set to 0 seconds, they will disable the timers’ functions
Control Type - Select whether the display on/off commands are sent using RS-232, TCP/IP, or
CEC
Display Mode -
DispSW AVon: Display switches on/off, source audio/video signal always on
DispSW AVSW: Display switches on/off, source audio/video signal switches on/off
AV SW: Display is always on, source audio/video signal switches on/off
TCP/IP Settings of Controlled Device
This option sets the IP for display control. The static IP set here should match the display’s static IP.
To set or view the display’s IP address, check the display’s user manual.
Note:
The switcher and the display must be on the same network for these commands to work
Note:
Be sure the static IP address set for the display does not match any other device on the network