AT-HDVS-SC-RX
26
The Web GUI
Display Auto Power On
Click this toggle switch to
ENABLE
to send the command to power-on the display when an A/V signal is detected.
Otherwise, set to
DISABLE
to turn this feature off.
Display Auto Power Off
Click this toggle switch to
ENABLE
to send the command to power-off the display when an A/V signal is no longer
present. Otherwise, set to
DISABLE
to turn this feature off.
Lamp cool down timer (Sec.)
Sets the cool-down interval, in seconds, before the projector can be powered-off. During this time interval, the
projector will not accept any “power on” or “power off” commands until the last “power off” command has been
processed and the projector lamp has completed the cool-down cycle. Range: 0 to 300.
Auto power off timer
Sets the time interval, in seconds, between when the loss of A/V signal is detected and when the “Display Off”
command is sent. Range: 5 seconds to 1 hour.
Control Type
Sets the control method for sending commands. The following options are available: RS-232, IP, CEC.
Feedback Verify
Sets the feedback verification state. Click the toggle to enable or disable this feature. The following options are
available.
Setting
Description
RS-232
RS-232 is used to send commands.
IP
Commands are sent over IP.
CEC
Uses CEC to send commands.
Setting
Description
On
This is the default setting. The AT-HDVS-SC-RX will make four attempts to
send the command, if the feedback string is not acknowledged. After the fourth
attempt, the process will fail.
Off
Sends the command and ignores the feedback string.
NOTE:
If using this timer with the Fallback Time interval (Auto-Switching), this value should be at
least six seconds longer that the Fallback Time interval. Refer to the
more information.