19
18
User manual
Pandora DXL-0100L/0101L service-security system
Level 4 Resetting to factory settings
To reset to the factory settings, you need to enter programming level 4, than press and hold
VALET button for 2 seconds until siren sounds. Once VALET button is released, the status indicator will
confirm a successful reset to factory settings with a long red flash.
Level 5 Programming of RHM-02 engine compartment module
1. Enter programming mode on level 5.
2. Connect wire 7 (OUT-RHM/programming) of RHM-02 module to wire 2 (ground) and connect
to the car grounding spot.
3. When wire 3 is connected (module power supply 12V), the system will confirm the module
recording to the system’s memory with 1 sound signal of the siren.
4. Disconnect programming wire 7 from wire 2 and insulate it.
Level 6, 7 Programming of radio relays 1 and 2
1. Connect the wire 1 of the radio relay to a grounded spot.
2. Select the desired level of the programming menu 6 or 7 for programming radio relays 1 or 2
respectively.
3. Apply power (+12V) on the contacts 3 and 4 of the radio relay. Siren will confirm radio relay
recording to the memory with 1 beep.
4. After a successful radio relay recording, contact 3 should be disconnected and insulated,
contact 4 should be connected to the constant power supply 12V or to the wire where there is a
constant 12V when ignition is switched on (according to the system settings).
Level 9 Changing firmware via the wireless interface 2,4 GHz
To change (update) the firmware using the wireless interface 2,4 GHz, enter programming level
9. After entering the system will await a wireless connection from the computer for 2 minutes. If the
waiting time limit has expired and the system was not connected to the computer, it will exit this level.
Level 10 Configuring system settings via the wireless interface 2,4 GHz
To change the configuration of the system using a wireless interface 2,4 GHz, enter programming
level 10, the system will confirm the entering with red flash of LED indicator. The system will await
a wireless connection from the computer for 2 minutes. If the waiting time limit has expired and the
system was not connected to the computer, it will exit this level.
Level 11 Programming validator code of immobilizer (Pin to Drive)
1. Select the button to set the secret validator code of immobilizer.
To do this, enter level 11 of programming and press the selected button (e.g. wheel ‘volume up’
button), LED indicator will confirm input with orange flashes. If there are no orange flashes when any
button is pressed, then this button is not recognized by the system, select a different button. After the
button was chosen, press VALET button. Security system will memorize the last pressed button (which
was pressed before VALET button) as a button to enter PIN-code of immobilizer and will await input
of the first digit of PIN-code.
2. Program the immobilizer deactivation PIN-code.
Enter the first digit by pressing the previously selected button (pause between pressing must be
no more than 1 second). The base unit will confirm entering with red flash of LED indicator.
Input the second (third, fourth) digit by pressing the previously selected button. The base unit will
confirm entering with red flash of LED indicator.
Input the required number of digits (up to 4) and then press VALET button. The system will
confirm receiving of the secret validator code with long red flash of LED indicator and will expect for
confirmation of PIN-code.
3. Confirm the immobilizer deactivation PIN-code.
Input PIN-code again similarly to the programming procedure and press VALET button. The
system will confirm correct PIN-code with red and green flashes of LED indicator and will memorize
PIN-code, then will proceed to the programming mode awaiting level input. Incorrect confirmation
is indicated with long red flash of LED indicator, after that the system will return to a programming
mode.
Level 15 Emergency disabling of immobilizer
To deactivate the immobilizer/Antihijack function, enter the programming level 15, the system
will confirm the entering with green flash of LED indicator. Input the first digit of the secret code using
VALET button (press the button a number of times, equal to the first digit; pauses between presses
should not exceed 1 second). The system will confirm input with red flash of LED indicator. Enter the
other three digits in the same manner. The correct input will be confirmed with 2 short sound signals
of the siren and with red flash of LED indicator. To activate immobilizer/Antihijack function, enter
level 15, LED will confirm input with red flash. Press VALET button once, siren will emit 1 short beep.