3 – DRILLING HOLES INTO THE CEILING
On the solid ceiling , draw the outline of the hole required to house the extractor hood based in
the chosen model.
The models E-250,E-260, E-270 are supplied with threaded rods which screw into the frame.
The adjusting nuts can be used to set the required height for the extractor hood ( between 210mm and
370mm).
Drill the 4 holes into the ceiling, following the measurements indicated on the drawing, , In-
sert the plugs supplied with the extractor hood into the holes and then screw in the rods.
OUTCUT:
1300 —- 1230 X 720
1600 —- 1485 X 720
1900 —- 1825 X 720
Page 3