User Manual For Cyclone LC Programmers
127
CS serial_file_3.ser
PS
CM algorithm_file_2
SS object_code_2
EM
PM
VC
CS serial_file4.ser
PS
CS serial_file5.ser
PS
12.4.1
Invoking A Serial File Via Command-Line
The command to invoke the serial number file in PEmicro’s interactive programming software is
“CS Choose Serial File”. The command to actually program the serial number to target and
automatically increment the serial number afterward is “PS Program Serial Number”.
PEmicro’s command line software uses the same commands in a command line fashion to invoke
the serial number file, initiate its programming, and increment:
CS serial_number_file.ser
PS
12.5
Creating A SAP Image With Multiple Serial Numbers
In the example shown in
, a SAP image was created that will select and program two
different serial numbers into different locations in memory as part of the programming sequence.
The first serial number counts by two with starting address 0x00020000 and the second serial
number counts by four with starting address 0x00021000.
As indicated by the programming sequence, first the Algorithm is selected, followed by the S19 file.
The part is erased, and then the s19 is programmed into the device. Once this is done, the first
serial file is selected and programmed, and then the second serial file. These same unique serial
numbers may be used by other SAP images, and each program will increase the serial number by
the designated count defined in the serial number file.
Figure 12-3: Cyclone Image Creation Utility: Serial Files In Programming Sequence