55
25
4.4.1- Warnings
Message:
Causes:
Acti on required:
“LACK OF SALT”
Lack of salt in the water
Add salt to the swimming pool
Incrustati ons or objects in the electrolysis
cell causing excess current
Clean the cell
The electrolysis cell is worn
Replace the electrolysis cell with a
new one
“EXCESS SALT”
Excess salt in the water
No acti on required if excess is not
very signifi cant
Incrustati ons or objects in the electrolysis
cell causing excess current
Clean the cell
“CLEANING”
The chlorinator is in the self-cleaning
process. The process lasts 5 minutes
None
“TEMPERATURE”
The ambient temperature is >40º
Try and place the equipment
in another positi on where it is
not over 40º or perform forced
venti lati on. Leave the equipment
to rest for a few minutes. Consult
secti on number 4. Installati on
The radiator fi ns are obstructed or are not
in a verti cal positi on.
Place the equipment so that air is
circulated for correct cooling
4.4.1.1- Additional warning messages
ORP or PPM value is
fl ashing
The redox or free chlorine probe are
balanced in automati c mode. When the
probe is balanced, the value remains set
None
pH value is fl ashing
The pH probe is balancing. When the probe
is balanced, the value remains set
None
Value ---o (Water
temperature) is fl ashing
The value of the water temperature is
under 15º.
None
pH min
The equipment is working under the
minimum set value.
Revisar el sistema de pH
pH max
The equipment is working above the
maximum set value.
Revisar el sistema de pH
ORP min
The equipment is working under the
minimum set value
Revisar sonda Redox
ORP max
The equipment is working above the
maximum set value
Revisar sonda Redox
Filter ti me
The equipment has switched off before the
ti me set in semiautomati c
Reanudar el ciclo de fi ltración
Summary of Contents for SMARTCL15127
Page 60: ...MIPA SMCL 150604...