45
4.2.2- Main screen
On starti ng up the equipment, a screen will be displayed with the main parameters.
• The upper line displays the producti on %, the voltage of the electrolysis cell and the water
temperature consecuti vely.(If you do not have a temperature probe, --- º will appear).
• The second line displays the oxidati on /reducti on potenti al called RedOx or ORP (Oxidati on
Reducti on Potenti al) or ppm if working with a free chlorine probe. “Man.”, “Auto” or “Semi-
auto” is displayed on the right.
• Important: If you do not have a RedOx probe or a free chlorine probe, the ORP reading
displayed may be a random value. When selecti ng the Manual mode (this mode is required if it
is to operate without a probe), the equipment will ask if you want to display the ORP line or to
conceal it.
• The third line displays the pH reading as long as it is fi tt ed in the equipment and the relay
status.
The fourth line displays the → Menu (press the OK butt on to access the menu) and the ti me on
the clock. If any alarm or warning occurs, it will also be displayed on this line.
4.2.3- Main menu
Press the “OK” butt on from the main screen to access the main menu.
Using the butt ons ↓↑ you can select a line of the menu, indicated by the arrow (→). The OK butt on is
used to confi rm the selecti on.
To access the confi gurati on menu, you need to confi rm the operati on by selecti ng (S) through
the arrow, ↑ and pressing OK.
C1: 98%
C1: 1.21ppm
pH: 6.7
→Menu
16 : 20
Relé OFF
Auto.
7 . 4V
6˚C
→Volumen, m3
Exterior
Cubierta, interr.
Flow switch:
N ↓
45 ↑
→Acido
pH Alarm:
SALIR
S
↑
→Configuración
Cloro
pH
Relé
↓
→Lengua
Control
Limpieza
4 h
...
↓
C1: 98%
C1: 1.21ppm
pH: 6.7
→Menu
16 : 20
Relé OFF
Auto.
7 . 4V
6˚C
→Volumen, m3
Exterior
Cubierta, interr.
Flow switch:
N ↓
45 ↑
→Acido
pH Alarm:
SALIR
S
↑
→Configuración
Cloro
pH
Relé
↓
→Lengua
Control
Limpieza
4 h
...
↓
Summary of Contents for SMARTCL15127