EN 8
Determine VOP value
If the VOP value is not known, you can identify it with a piece of cable of
known length. (minimum 10 m)
Connect a cable of known length to the KLM-2000.
In the Function menu, select the VOP menu and then the VOP Test
feature.
With SET, you activate the edit mode. (Font white with black background)
Use UP and DOWN to adjust the length.
TEST / OK calculates the VOP value.
You can now edit the name, type, and manufacturer of the cable in the
same way. (Max 6 characters, confirm each letter individually with SET, or
delete with cable croup-key.)
Save your input with TEST / OK.
With EXIT / POWER you return to the menu.
Edit VOP Value
If the VOP value of a cable is known, it can be stored directly.
In the Function menu, select the VOP menu and then the VOP Set feature.
Edit the name, type and manufacturer as well as the VOP value of the
cable as described above.
For coax cables, you can set the impedance 51, 75, or 100 Ω.
With EXIT / POWER, you save the values and return to the VOP menu.
Summary of Contents for PAN KLM-2000
Page 1: ...MANUAL PAN KLM 2000 ...
Page 2: ...F i g 1 F i g 2 ...
Page 4: ...DE 1 Bedienungsanleitung PAN KLM 2000 Kabellängenmessgerät ...
Page 16: ...EN 1 Manual PAN KLM 2000 Cable length meter ...
Page 27: ...FR 1 Manuel d instructions PAN KLM 2000 Longueur du câble de compteur ...
Page 39: ...IT 1 Istruzioni per l uso PAN KLM 2000 Misuratore lunghezza del cavo ...
Page 51: ...NL 1 Gebruiksaanwijzing PAN KLM 2000 Kabellengte meter ...
Page 62: ...SE 1 Bruksanvisning PAN KLM 2000 Kabellängd mätare ...
Page 73: ...SK 1 Návod na používanie PAN KLM 2000 Dĺžka kábla meter ...
Page 84: ...HU 1 Használati útmutató PAN KLM 2000 Méteres kábelhossz ...
Page 95: ...SI 1 Navodila za uporabo PAN KLM 2000 Dolžina kabla merilnika ...
Page 106: ...HR 1 Upute za uporabu PAN KLM 2000 Dužina kabela mjerni ...
Page 117: ...RO 1 Instrucţiuni de folosire PAN KLM 2000 Lungime cablu metru ...