Data sheet
35
10.
Data sheet
10.1
Data sheet 1
JOb No.
Set item
Symbol
Unit
Set range
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
SOL output
SOL
SOL
I
or SOL
II
Pressure control
output
Pr
MPa
0.00 - 0.50
Squeeze delay
time
Tsd
C
ycle
0 - 99
Squeeze time
Ts
C
ycle
3 - 99
Up-slope time
Tu
C
ycle
0 - 20
Weld time 1
Tw
1
C
ycle
0 - 99
Welding current 1
(Constant current
compensation)
I
1
A
15 - 500 X100
Welding current 1
(Voltage
compensation)
0 - 99
Cooling time
Tc
C
ycle
0 - 99
Weld time 2
Tw
2
C
ycle
0 - 99
Welding current 2
(Constant current
compensation)
I
2
A
15 - 500 X100
Welding current 2
(Voltage
compensation)
0 - 99
Down-slope time
Td
C
ycles
0 - 20
Hold time
TH
C
ycle
0 - 99
Off time
To
C
ycles
0 - 99
(
*
1)
Number of
pulsations
Pu
Time
0 - 9
(
*
2)
Current upper limit
Iup
%
0 - 20
Current lower limit
Idn
%
0 - 20
(*1): When the “Off time” is set at “0”, one-spot welding will be executed, and it is set to “1” or above, repeated welding will be
executed.
(*2): When the “Number of pulsations” is “n” (n
≠
0), the cooling time and weld time 2 are repeated (n+1) times, and the down-slope
time occurs only after the (n+1)th weld time 2. When the weld time 2 is set to “0” cycle, it is not possible to set the number of
pulsations to “1” or above. (Setting error)(
SEQUE
NCE, etc.
MON
IT
O
R
Summary of Contents for YF-0201Z5HGF
Page 22: ...TSMP222 TSM222 ...
Page 33: ...8 Circuit diagram Circuit diagram 33 TSMP222 YF 0201Z5HGF Circuit diagram ...
Page 37: ......