Advanced functions
25
7.
Advanced functions
7.1
DIP switches (DPSW1, DPSW2) settings
• All the DIP switches are factory set to OFF side at
shipment.
• Prior to changing the DIP switch settings, turn off both
control power and welding power. Changing the DIP
switch settings while those powers are on doesn’t
update the changes.
• Refer to the following table for description.
Select desirable functions with dip switches on the P.C.
board
TSMP222
*.
TSMP222
*
DPSW2
DPSW1
JP1
JP2
(Front)
DPSW1
No.
Function
ON
OFF
DPSW1-1
Start mode
15 schedules
(Binary code)
4 schedules
DPSW1-2
Control speed
(*1)
0.5 cycle
1 cycle
DPSW1-3
Trouble mode
Major Trouble
Minor Trouble
DPSW1-4
Start signal is held
(*2)
at start of sequence
at start of welding
DPSW1-5
Control mode
Voltage fluctuation
compensation control
Constant current control
DPSW1-6
Selection of constant current
(*1)
Primary CT
Secondary troidal
DPSW1-7
Detection of tip sticking
Can be done
Non
DPSW1-8
Re-weld mode
Can be done
Non
DPSW1-9
Selection of current off
Current stop
Sequence stop
DPSW1-10
Mode of increase current
Signal up
Step up
DPSW2
No.
Function
ON
OFF
DPSW2-1
Pressure Ctrl
Can be done
Non
DPSW2-2
Keep it to OFF at all times
DPSW2-3
Counter mode
Decrease
Increase
Note
• Turn off “Control Power Switch” before setting DIP switches.
•
(*1)
In case of using this product with
• A single-phase AC type welder with the primary CT: Set
[DPSW1-2] OFF / [DPSW1-6] ON
.
• A single-phase DC type welder: Set
[DPSW1-2] ON / [DPSW1-6] ON
.
•
(*2)
“Start signal is held” function is to select holding timing.