Advanced functions
7.6
Selecting functions
Use JP1, JP2 or DPSW on the PC Board (
TSMP222
*)
to select functions.
(
1
)
JP1: short plug
Set to select either “Normally open contact” or “Normally
closed contact.” for trouble output
(
2
)
JP2: Short plug
Set to select either “Production” or “Step-up” counter
completion output.
7.7
Installing the specific C.T.
1)
Install C.T.
• Refer to the figure on the right to install the C.T.
to the welding power source.
In case of installing for the first time, install it so that it
passes through any one of the cables A, B and C.
2)
Set the DPSW1-6 (DIP switch) to the ON (Primary CT) side.
3)
Set the DPSW1-2 (DIP switch).
Contact
type
Normally open
Normally closed
Setting
Default setting
-
Output
type
Production
counter
completion output
Step-up (or signal-up)
counter completion
output
Setting
Default setting
-
TSMP222
*
DPSW2
DPSW1
JP1
JP2
(Front)
When this product is used with a welding power source that is a primary constant current type or for a single-phase
DC type, it is not possible to use the toroidal coil. In that case, it is necessary to use
a specific C.T.
(C.T. with resistor). Depending on model numbers, the C.T. is provided as accessory. (See section “Distinctions”.) If
not, please prepare the specified C.T. separately.
Welding
transformer
(a)
Primary constant current type welding machine
Set to OFF (1 cycle) side.
(b)
Single-phase DC type welding machine
Set to ON (0.5 cycle) side.
3
0