42
Before asking for repairs, check the symptoms with the following table.
Contact your dealer if a problem cannot be solved even after checking and trying the solution in the
table or a problem is not described below.
Symptom
Cause/solution
Reference
pages
Power is not turned on.
When using DC power supply
SW316L
SW316
• Is 12 V DC power supply connected to the 2P
power supply cable?
→
Check whether the connection is appro-
priately established.
• Is the AC adaptor in use compliant with the
Specifications?
→
Check the Specifications regarding AC
adaptor.
When using a PoE device for power supply
• Are the PoE device and the network cable of
the camera connected using a LAN cable?
→
Check whether the connection is appro-
priately established.
• Depending on the PoE device, the power sup
-
ply will stop when the demanded power
exceeds its total power limit for all PoE ports.
→
Refer to the operating instructions of the
PoE device in use.
21
When the IR LED lights a
part or all of the screen
appears blurred.
• Is there a wall or other reflecting surface or
object near the camera (including areas not
displayed in images)?
SW316L
→
Adjust the camera angle so that light from
the IR LED is not reflected.
29
When the IR LED lights
the camera switches
between color mode and
black-and-white mode.
• The subject may be too close to the camera.
SW316L
→
Adjust the distance between the camera
and the subject.
29
Troubleshooting