29
z
Be sure to view the monitor for adjustment when the camera angle is adjusted.
Supply power to this unit, connect the monitor for adjustment (e.g. a small LCD) to the monitor
output jack, and adjust the camera angle (turn off the power after view angle adjustment for safety).
q
Loosen the 4 fixing screws of the front cover to remove the front cover.
w
Connect the monitor output jack and the monitor for adjustment with the RCA pin cable
(locally procured).
<Front cover> (This illustration represents WV-SW316.)
e
Repeat the steps (1) and (2) to adjust the camera angle.
(1) Loosen the panning lock screw and rotate the camera head horizontally to adjust panning.
(2) Loosen the tilting lock screw and rotate the camera head vertically to adjust tilting.
(3) Tighten the panning lock screw and tilting lock screw after camera angle adjustment.
IMPORTANT:
•
After camera angle adjustment, the panning lock screw and tilting lock screw shall be securely tightened.
Recommended tightening torque: 2.45 N·m {1.8 lbf·ft}
Tilting lock screw
Panning lock screw
Notes:
• Use a hexagonal wrench with width across flats of 4 mm (locally procured) to loosen or tighten
the panning lock screw and tilting lock screw.
• Approximately 1 rotation of loosening the panning lock screw and tilting lock screw allows cam
-
era angle adjustment. Do not loosen the screws beyond necessity.
• The camera body shall be held when the panning lock screw or tilting lock screw is loosened.
• Focus adjustment (
☞
page 30-32) shall be performed at the same time panning and tilting
adjustments are performed.
Adjustment
Fixing screw x4
Front cover
Monitor output jack