8 Configure the malfunction notification
settings [Failure Notif.]
The settings relating to the notification destination when an error occurs in the microphone element can be
configured on the “Failure Notif.” page. (
Panasonic alarm protocol notification
[Panasonic alarm protocol]
Select “On” or “Off” to determine whether or not to provide notification by Panasonic alarm protocol when an
error occurs in the microphone element.
•
Default:
Off
Note
•
When “On” is selected, notification of the alarm occurrence will be provided to the registered destination
server addresses in order (to IP address 1 first, to IP address 4 last).
[Destination port]
Select a destination port for the Panasonic alarm protocol from the following.
•
Available range:
1 - 65535
•
Default:
1818
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670
[Retry times]
Select a retry time for the Panasonic alarm protocol.
•
Available range:
0-30
•
Default:
2
26
Operating Instructions
8 Configure the malfunction notification settings [Failure Notif.]