17
Check before installation
Compatibility of devices is restricted. Before
installation, check the ratings and dimensions
of the devices to be used.
Contact your dealer for details.
Before installation
•
SFV781L
Use the provided attachment plate or base
bracket.
SPV781L
Directly secure the camera mount bracket
or use the provided adapter box.
• Anchor bolts and screws used to mount
the camera on the ceiling or wall are not
supplied. Prepare bolts and screws that
match the structure and materials of the
installation location and satisfy the perfor-
mance and reliability specifications shown
below.
SFV781L
Required screws: M4 (4 pcs.)
Minimum pull-out strength: 539 N {121 lbf}
(per 1 pc.)
SPV781L
Required screws: M5 (4 pcs.)
Minimum pull-out strength: 724 N {163 lbf}
(per 1 pc.)
Screw tightening
• The screws and bolts must be tightened
with an appropriate tightening torque
according to the material and strength of
the installation area.
• Do not use an impact driver. Use of an
impact driver may damage the screws or
cause tightening excessively.
• When a screw is tightened, make the
screw at a right angle to the surface. After
tightening the screws or bolts, perform
checks to ensure that the tightening is
sufficient enough so that there is no
movement or looseness.
Do not remove or loosen the screws on
the bottom of this product.
SFV781L
If the screws (9 pcs.) are loosened, water
exposure may cause damage or malfunction of
the product, or dropping may result in injury.
SPV781L
If the screws (4 pcs.) are loosened, the camera
may fall, resulting in accidents.
Take notice of humidity
Install this product when the humidity is low. If
installation is performed when it is raining or in
very humid conditions, the inside may be
affected by humidity, causing mist-over inside
the dome cover
SFV781L
or front cover
SPV781L
.