background image

3

Periodic inspections shall be conducted.

• 

Rust on the metal parts or screws may cause a fall of the product resulting in injury. Consult the 
dealer for the inspections.

Do not rub the edges of metal parts with your hand.

• 

Failure to observe this may cause injury.

Consult the dealer about the installation area to select a strong ceiling area. Make sure that the 

• 

installation area is strong enough to hold the total weight of the camera assembly (approx. 2.8 k

g

 

{6.13 lbs.}) before installation.
The installation area shall have 210 mm {8-9/32"} or more space behind the ceiling.

• 

210 mm {8-9/32"} or more

Ceiling board: between 9 mm {3/8"} 

and 40 mm {1-9/16"}

The thickness of the ceiling board for installation can range between 9 mm {3/8"} and 

• 

40 mm {1-9/16"}.
Avoid installing in the following locations.

• 

Locations where it may get wet from rain or water splash (not only outdoor)

• 

Locations where a chemical agent is used such as a swimming pool

• 

Locations subject to steam and oil smoke such as a kitchen

• 

Locations near flammable gas or vapor

• 

Locations where radiation or x-ray emissions are produced

• 

Locations subject to strong magnetic field or radio waves

• 

Locations where it may be damaged by briny air such as seashores

• 

Locations where the temperature is not within -10 

C- + 50 

C {14 

F - 122 

F}.

• 

Locations subject to vibrations (This product is not designed for on-vehicle use.)

• 

Locations where the temperature may rapidly change such as the peripheral areas of the air 

• 

outlets of air conditioners or doors facing outside. (In case of installing the camera in such 
locations, the dome cover may become foggy or condensation may be caused on the 
cover.)

The screws and bolts must be tightened with an appropriate tightening torque according to the 

• 

material and strength of the installation area. After tightening the screws or bolts, perform visual 
check to ensure tightening is enough and there is no backlash.

Summary of Contents for WV-Q126

Page 1: ...or operate this product please read these instructions carefully and save this manual for future use The model number is abbreviated in some descriptions in this manual Operating Instructions Ceiling Mount Bracket Model No WV Q126 ...

Page 2: ...of the camera for supported cameras The screws and fixation mechanisms shall be tightened securely Failure to observe this may cause a fall of the camera resulting in injury The measures of protection against a fall of the camera shall be taken Failure to observe this may cause injury Be sure to install the safety wire Select an installation area that can support the total weight If a selected are...

Page 3: ... not only outdoor Locations where a chemical agent is used such as a swimming pool Locations subject to steam and oil smoke such as a kitchen Locations near flammable gas or vapor Locations where radiation or x ray emissions are produced Locations subject to strong magnetic field or radio waves Locations where it may be damaged by briny air such as seashores Locations where the temperature is not ...

Page 4: ...rating Controls Installation sample Safety wire angle Accessory Safety wire Accessory Decorative cover Ceiling mount bracket Camera Ceiling board Roof space Decorative cover Camera mounting stage Mounting chassis ...

Page 5: ...ns during Step 1 Perform Step 1 to make sure the desired brand logo direction matches the Brand logo side setting on Template A Also pay attention to this setting when per forming Step 6 later Install two anchor bolts M10 recommended into the concrete ceiling 2 Determine the anchor bolt length by use of Template B accessory 1 Position the nut by use of Template B accessory The distance between the...

Page 6: ...in Note To use the anchor bolt that was already installed the use of 2 spacer nuts is helpful Spacer nuts Safety wire Spacer nuts Safety wire angle Existing anchor bolt 4 Remove the camera mounting stage Remove the 6 screws M4 1 Rotate the camera mounting stage 2 a half turn clockwise Lift the camera mounting stage and 3 remove it Upper side Lower side Safety wire 2 Insert 1 Disconnect 3 Bend Mark...

Page 7: ...rocedure 14 is set according to the direction the mount ing chassis is inserted see the below illustration Ceiling board fixing bracket 4 3 lines Use the ceiling board fixing bracket as a guide Align the brand logo with the ceiling board fix ing bracket which is nearly in the center of the 2 groups of 3 lines Direction of the brand logo on the decorative cover Safety wire Accessory Mounting chassi...

Page 8: ...of the mounting chassis and ceiling board fixing bracket resulting in mounting chassis securing Recommended tigtening torque 0 78 N m 0 58 lbf ft Secure the top of the mounting chas 3 sis with double nuts Important When securing this bracket on the ceiling make sure that the four ceil ing board fixing brackets are open as shown in the figure Prepare the cables 8 Run the cables from the space of th...

Page 9: ... camera mounting bracket is an accessory of the camera The base unit is attached in figures shown in the following descriptions Important Make sure to attach the camera mounting bracket in correct direction If you attempt to attach it in the wrong direction some part of it will interfere with the camera mounting stage Do not try to forcibly attach it as it may cause a failure or falling Correct di...

Page 10: ...op per Caution If it is difficult to move grasp the flanges and legs and rotate Insert and tighten the 3 screws you 3 removed in Step 4 Refer to Fig A Recommended tightening torque 1 57 N m 1 16 lbf ft Insert and tighten the 3 screws you 4 removed in Step 4 Refer to Fig B Recommended tightening torque 1 57 N m 1 16 lbf ft Important Do not let the cables be caught during installation work Flanges L...

Page 11: ... install the camera Important Make sure you hold the cam era main unit when you attach it Holding the camera dome cover during attachment may cause damage to the cover Remove the protective sheet from the camera dome cover 13 14 Mount the decorative cover Align the 3 lines on the side of the dec 1 orative cover with the 3 lines on the mounting chassis to attach Turn the decorative cover clockwise ...

Page 12: ...mplate A 1 sheet Template B 1 sheet Decorative cover 1 pc Screw M4 5 pcs inc 1 spare screw Ambient temperature 10 C 50 C 14 F 122 F Dimensions 245 mm 9 29 64 in diameter x 188 8 mm 7 in height including the decorative cover Weight Approx 1 2 kg 2 65 lbs Finish Main body Surface treatment steel sheet Decorative cover ABS resin with silver metallic coating ...

Reviews: