Waterproof treatment for the cable joint sections
Adequate waterproof treatment is required for the cables when installing the camera with
cables exposed or installing it under the eaves. The camera body is waterproof, but the cable
ends are not waterproof.
Be sure to use the supplied butyl rubber tape at the points where the cables are connected to
apply waterproof treatment in the following procedure. Failure to observe this or use of a tape
other than the provided butyl rubber tape (such as a vinyl tape) may cause water leakage
resulting in malfunction.
When using a LAN cable
When using the ALARM IN/OUT cable, POWER cable, MIC/LINE IN cable and AUDIO OUT
cable
Important:
• Waterproof treatment is also to be applied to the 2P power cable (provided), the 4P alarm
cable (provided) and other connection cables if they are subject to rain.
Note:
• How to wind the supplied waterproof butyl tape
Stretch the tape by approx. twice (see the illustra-
tion at right) and wind it around the cable.
Insufficient tape stretch causes insufficient water-
proofing.
• To install this product outdoors, be sure to water-
proof the cables. Waterproof grade (IEC IP66 or
equivalent) is applied to this product only when it is installed correctly as described in
these operating instructions and appropriate waterproof treatment is applied. The mount
brackets are not waterproofed.
Wind the tape in a half-overlapping manner
Wind the tape in a half-overlapping manner
2x
Stretch the tape to about twice.