39
[Upside-down]
Select "ON (desktop)" or "OFF (ceiling)" to determine
how the camera is to be installed.
ON (desktop):
Select this when the camera is to be
installed with the dome side up.
OFF (ceiling):
Select this when the camera is to be
installed with the dome side down.
Default:
OFF (ceiling)
[EL-ZOOM]
Select "ON" or "OFF" to determine whether or not to use
the electronic zoom.
ON (Max X10):
Images can be zoomed in on with the
optical zoom (1x - 22 x) and the electronic zoom
(23x – 220x).
OFF:
Does not use the electronic zoom.
Default:
OFF
Notes:
• When "ON" is selected, zooming will stop when the
zoom factor has reached 22x.
• When the zoom factor is increased to 22x (EL-zoom)
or more, the image resolution will be lower.
• When the zoom factor is 22x or more, the setting of
the preset positions will become unavailable.
[Pan·Tilt degree/Zoom ratio display]
Select "ON" or "OFF" to determine whether or not to dis-
play the current panning/tilting degree and the zoom
factor on images when the camera is being operated
manually.
ON:
Displays the current panning/tilting degree and the
zoom factor.
OFF:
Does not display the current panning/tilting degree
and the zoom factor.
Default:
ON
Note:
When "ON" is selected, the panning/tilting degree
and the zoom factor will be displayed at the position
selected for "OSD Position" on the [Basic] tab of the
"Basic setup" page. (
☞
page 25)
[Tilt Angle]
Select the maximum degree for tilting from the following.
(Level = 0°)
0°/–5°/–10°/–15°/–20°/–25°/–30°
Default:
0°
Note:
When using an optional inner cover WV-Q153,
upper side of images will be hidden (become black)
when the tilt angle of the camera is almost level.
(When "–5°" is selected for "Tilt Angle" on the setup
menu, upper half of images will be hidden.)
In this case, images will also be washed out depend-
ing on the object when "ON" is selected for "AGC"
on the setup menu.
Refer to the network operating instructions (PDF) for
further information about the setup menu.