CONNECTIONS
-19-
Pin no.
Power source
1
2
3
4
24 V AC LIVE
24 V AC NEUTRAL
Ground
Not use
Alarm In/Out Ratings
Alarm In
:
5 V DC pull-up input. Drive capacity of at
lease 0.2 mA required.
OFF :
4 V DC minimum 5 V DC maximum,
or open
ON :
1 V DC maximum or short
Alarm Out :
Open collector output. 16 V DC, 100 mA
maximum drive capacity
OFF :
Open
ON :
100 mA maximum
* When connecting to an external device, set up the
system so the ratings are not exceeded.
Note:
Do not turn off camera power within 30 seconds
after turning it on. Doing so can cause pan, tilt, zoom,
or focus to go out of position.
Precautions
• The following connections should be made by qualified service personnel or system installers in accordance
with all local codes.
• See the reverse side of the cover page for main lead connection.
• Turn off the power at the fuse box before starting the installation work, or it so could result in fire, electric shock,
personal injury, and material damage.
#24
(0.22mm
2
)
Copper wire size
(AWG)
Length
of cable
(approx.)
(m)
(ft)
#22
(0.33mm
2
)
#20
(0.52mm
2
)
#18
(0.83mm
2
)
20
30
45
75
65
100
160
260
• 24 V AC Power Supply Connection
Recommended wire gauge sizes for 24 V AC line
Accessory Connector Information
1
3
2
4
RS485 Data Port
Alarm Input Connector
Alarm Output Connector
T(B)
T(A)
R(B)
R(A)
Red
Orange
Yellow
Green
Data
Tx
Data
Rx
(RJ-12)
Alarm In 2 (Red)
Alarm In 1 (Black)
GND (Brown)
Alarm In 3 (Yellow)
Alarm In 4 (Blue)
GND (Orange)
GND (Light Blue or Green)
GND (Violet)
Alarm Out 2 (Pink)
Alarm Out 1 (Grey)
GND (White)
GND (Light Green
or Light Blue)
220 V - 240 V AC
(WV-CW
9
60)
24 V AC (WV-CW
9
64)
Coaxial Cable RG-6/U (5C-2V)*2
24 V AC Cable for camera
RS485 Data Port
To VIDEO IN port
(CAMERA IN)
8P Alarm Cable (provided)
4P Alarm Cable (provided)
To sensor, etc.
To buzzer,
display device, etc.
To Matrix Switcher,
etc.
Video Output
Connector
Alarm Input
Connector
Alarm Output
Connector
Twisted Pair Cable*1
(BNC)
(RJ-12)
*1: For twisted pair cable, use shielded low-impedance cable with a thickness of at least AWG#22
(0.33 mm
2
).
*2: Keep the overall length of coaxial cable under 1200 meters (in the case of RG-6/U (5C-2V)).
*3: Be sure to connect the grounding cable to ground.
WV-CW960G̲CW964E̲US 08.12.4 10:49 AM ページ19