37
(2) ALC Mode with SUPER-D2 OFF
1. Move the cursor to the SUPER-D2 parameter and select OFF.
(When you select MANUAL, SUPER-D2 is not available.) The item
MASK SET appears on the menu.
2. Move the cursor to MASK SET and press the CAM (SET) key. The
48 mask areas appear on the monitor screen. The cursor is blink-
ing in the top left corner of the screen.
3. To mask an area where backlight is bright, move the cursor to that
area then press the CAM (SET) key. The mask turns white. Repeat
this procedure to mask the desired area.
4. To cancel a masked area, move the cursor to that area, then
press the CAM (SET) key. To cancel all masking area, press the
F2 button of the WV-CU550B. (For the WV-RM70, press the right
and left switches simultaneously.)
5. After masking is completed, press the MON (ESC) key. The 48
mask areas on the monitor screen disappear and the field setup
menu appears.
6. If you want to change the video output level (picture contrast),
move the “I” cursor for LEVEL and adjust the level.
7. Move the cursor to RET and press the CAM (SET) key to return to
the CAM SET UP menu. (To return to the camera picture, press
the F4 button.)
Blinking
Blinking
Blinking
Turns to white
** ALC CONT **
BACK LIGHT COMP
SUPER-D2
MASK SET
LEVEL
RET
OFF
••••|••••
- +
** ALC CONT **
BACK LIGHT COMP
SUPER-D2
MASK SET
LEVEL
RET
OFF
••••|••••
- +