31
●
Alarm IN/OUT (ALARM IN/OUT)
Move the cursor to ALARM IN/OUT, then press the CAM (SET) key.
ALARM I/O submenu appears.
Note:
While the camera is in AF mode or the lens moves between
WIDE and TELE alarm input may be ignored if several alarm
inputs are received in succession.
ALARM IN 1-4
Alarm input signals are supplied from external devices through
the ALARM IN connector to turn the camera to a preset position.
1. Move the cursor to ALARM IN 1* and select a preset position or
OFF by moving the joystick, then press the CAM (SET) key.
* Set ALARM IN 2, 3 and 4 in the same way as ALARM IN 1.
1 POSI, 2 POSI, 3 POSI, 4 POSI:
Preset position. If an alarm input
is received, the camera turns to a preset position, then sends
alarm output signal. Position number correspond to alarm
input numbers (1-1, 2-2, 3-3 and 4-4).
B/W:
Available for ALARM INPUT 4 only. The camera changes its
mode from colour to black and white if ALARM IN 4 is
supplied.
OFF:
The camera ignores alarm inputs.
Note:
If two or more alarm inputs are received while the camera is
moving to a preset position, the camera starts to aim at preset
positions in small preset numerical order after current
positioning.
** SPECIAL 1 **
PRIVACY ZONE
PROPO.P/T
AREA TITLE
PATROL
ALARM IN/OUT
PASSWORD LOCK
CLEANING
EL-ZOOM
PRESET ALM
IMAGE HOLD OFF
RET
OFF(ENB)
ON
ON(USER)
STOP
OFF
OFF
ON
OFF
Special 1 menu
** ALARM IN/OUT **
ALARM IN 1
ALARM IN 2
ALARM IN 3
ALARM IN 4
CNT-CLS 1
TIME OUT
CNT-CLS 2
COAX ALM OUT
RET
OFF
OFF
OFF
OFF
OFF
100MS
OFF
OFF
ALARM I/O submenu
CNT-CLS 1-2 (Output)
Two contact closure signals (Open collector type) are output through the ALARM OUT connector.
1. Move the cursor to CNT-CLS 1, then select OFF, ALARM or AUX 1 by moving the joystick to the right
or left.
When ALARM is selected, TIME OUT appears. Select an appropriate duration from among 100 MS,
200 MS, 1000 MS (1 s), 2000 MS (2 s), 4000 MS (4 s) by moving the joystick to the right or left.
Note:
The shorter the duration, the more frequent will be the detection output.
2. Move the cursor to CNT-CLS 2, then select OFF, B/W or AUX 2 by moving the joystick to the right or
left.
OFF:
Contact closure signals are inactivated.
ALM:
Available for CNT-CLS 1 only. Motion detection is output.
AUX 1(2):
An alarm signal is output when the camera receives a command from the controller.
B/W:
Available for CNT-CLS 2 only. ON (active) is output when the camera operates in black and
white mode if ALARM IN 4 is set to B/W.
Note:
We recommend that you set the connected external device to ignore the shorter alarm outputs
of 90 ms or less from the camera.