-10-
Type of
RG-59/U
RG-6U
RG-11/U
RG-15/U
coaxial cable
(3C-2V)
(5C-2V)
(7C-2V)
(10C-2V)
Recommended
(m)
250
500
600
800
maximum
cable length
(ft)
825
1 650
1 980
2 640
3. Wiring precautions:
• Do not bend the coaxial cable into a curve whose
radius is smaller than 10 times the cable’s diame-
ter.
• Never staple the cable even if with circular sta-
ples. Impedance mismatching will occur.
•
Never crush or pinch the cable.
All of the above will change the impedance of the
cable and cause poor picture quality.
Installation of Auto Iris Lens Connector
Install the lens connector (YFE4191J100) when using a
video drive ALC lens.
The installation should be made by qualified ser-
vice personnel or system installers.
(1) Cut the iris control cable at the edge of the lens
connector to remove the existing lens connector
and then remove the outer cable cover as shown
in the diagram below.
The pin assignment of the lens connector is as fol-
lows:
Pin 1: Power source; +9V DC, 50mA Max.
Pin 2: Not used
Pin 3: Video signal; 1.3 V[p-p]/40 k
Ω
Pin 4: Shield, ground
Pin 3
Pin 4
Pin 2
Rib
Pin 1