![background image](http://html.mh-extra.com/html/panasonic/wv-clr930/wv-clr930_operating-instructions-manual_277790053.webp)
53
**RS485 SETUP**
UNIT NUMBER 1
BAUD RATE 19200
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
XON/XOFF NOT USE
WAIT TIME OFF
ALARM DATA AUTO2
DELAY TIME ---
RET TOP END
RS485 Communication Setup [RS485 SETUP]
The necessary setups to use the RS485 communication function are performed.
"COMMUNICATION" is selected through the top screen and the "RS485 SETUP" screen is
called.
Refer to pages 24 and 25 for how to call up the screen.
Selection of camera unit number [UNIT NUMBER]
The unit number (1-96) of the camera that is controlled via the RS485 communication interface
is selected. (Default setting: 1)
Selection of data baud rate [BAUD RATE]
The data baud rate is selectable from the following:
2400/4800/9600/19200 (default) bps
Selection of data bit [DATA BIT]
The communication data length is selectable from the following:
7/8 (default) bits
Selection of parity check [PARITY CHECK]
The transmission error check method at communication is selectable from the following:
NONE (default):
No parity check
EVEN:
Even parity
ODD:
Odd parity
Selection of stop bit [STOP BIT]
The stop bit is selectable from the following: